Loading...
ST9902-LR061201 (2) Concrete Compression Test Report eM J ENGINEERING, INC. 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Project: City of Coppell -.--. West Sandy Lake Road Reconstruction Report Distribution: CMJ Report No.: 687-5192-192 Report Date: 12/19/2006 h/~ (1) City of Coppell (1) City of Coppell (1) Tiseo Paving Company (1) Teague Nail & Perkins Strength Slump Air Content Specifications 3500 psi @ 28 Days 4 in max 3 % min 6 % max n/a Placement Date Sampled By Weather Supplier/Mix Air Content Method Concrete Temperature Ambient Temperature 400 F min Test Data 11/16/2006 Jon Lewis Clear/Calm Redi Mix/732 ASTM C231 Ticket Number: Slump: Concrete Temperature: Placement Location: 180430 3.5 in 700 F Stamped Concrete: Time Batched: 10:38 Time Sampled: 11 :30 Air Content: 4.2 % Unit Weight: N/A Ambient Temperature: 550 F Yardage (c.y.): 10 of 10 Center Median at Intersection of Sandy Lake Rd and North Coppell Rd Sample Location: 5' South, 10' West of Northeast Comer of Paved Median Concrete Compression Test Results Set # Cylinder Age Max Load Area strenHth Fracture # Test Date (days) (Ibs. force) (sq.in.) (pSI Type 01 SLR11160601 11/27/2006 11 135240 28.18 4800 E-columnar 01 SLR11160602 12/14/2006 28 154200 28.09 5490 E-columnar 01 SLR11160603 12/14/2006 28 156050 28.09 5560 E-columnar 01 SLR 11160604 Hold 28 day average 5530 Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. 10 Gallons of Water Added On-Site, approved by: Paving Foreman wlTiseo rt~lrff CMJ Engineering, Inc R. Carl Lee, S.E.T. Vice President/CMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. o I Page 1 of 1 Concrete Compression Test Report eM J ENGINEERING, INC. 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Project: City of Coppell West Sandy Lake Road Reconstruction Report Distribution: (1) City of Coppell (1) City of Coppell (1) Tiseo Paving Company (1) Teague Nail & Perkins CMJ Report No.: 687-5192-192 Report Date: 12/01/2006 Strength Slump Air Content Concrete Temperature Ambient Temperature Specifications 3500 psi @ 28 Days 4 in max Test Data 3 % min 6 % max n/a 400 F min Placement Date Sampled By Weather Supplier/Mix Air Content Method 11/16/2006 Jon Lewis Clear/Calm Redi Mix/732 ASTM C231 Ticket Number: Slump: Concrete Temperature: Placement Location: 180430 3.5 in 700 F Stamped Concrete: Time Batched: 10:38 Time Sampled: 11:30 Air Content: 4.2 % Unit Weight: N/A Ambient Temperature: 550 F Yardage (c.y.): 10 of 10 Center Median at Intersection of Sandy Lake Rd and North Coppell Rd Sample Location: 5' South, 10' West of Northeast Corner of Paved Median Concrete Compression Test Results Cylinder Age Max Load Area Set# # Test Date (days) (Ibs. force) (sq.in.) 01 SLR11160601 11/27/2006 11 135240 28.18 01 SLR11160602 12/14/2006 28 01 SLR11160603 12/14/2006 28 01 SLR11160604 Hold Stren.9th (pSI) 4800 Fracture Type E-columnar Normal cylinder size: 6" x 12" Field and laboratory lests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. 1 0 Gallons of Water Added On-Site, approved by: Paving Foreman w/Tiseo CMJ Engineering, Inc R. Carl Lee, S.E.T. Vice President/CMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. 01 Page 1 of 1