Loading...
Coppell Trade 2-LR061127FARGO OONSULTANTB, ZNC. 11440 Reeder Rd. • Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Puge 1 o j'2 REPORT OF FIELD COMPACTION Tested For: Holt Lunsford Commercial Date Performed: 11/27/2006 Project Name: Coppell Trade Center Building D FARGO Project No. M06-1165 Coppell, Texas Density: Per ASTM D-2922 Gauge Manufacturer: Humboldt Moisture: Per ASTM D-3017 Gauge Model: HS-SOOlEZ Test Mode: Direct Transmission Probe Depth: 8 inches Moisture-Density Relations Proctor No. Material Description Optimum Moisture(%) Max. Dry Density (pc,~ 1 Reddish Brown SandyClay 19 106 1 LT Reddish Brown and Tan Sandy Clay (lime treated) 23.5 97 Field Test Results Test Elevation Location Proctor DryDensity Percent Percent No. /Lift No (pcf) Moisture Density 46 SG Paving, 16'N by 87'E from NW building corner 1 102.5 20.5 96.7 47 SG Paving, 16'N by 168'E from NW building corner 1 104.6 19.3 gg,7 48 SG Paving, 23'N by 310'E from NW building comer 1 104.1 19.3 98.2 49 SG Paving, 18'N by 425'E from NW building corner 1 101.4 20.5 95,7 50 SG Paving, 84'N by 566'E from NW building corner 1 103.6 21.2 97.7 51 SG Paving, 77'N by 394'E from NW building corner 1 104.5 19.8 gg•g 52 SG Paving, 62'N by 288'E from NW building corner 1 101.9 19 gg,1 53 SG Paving, 50'N by 153'E from NW building corner 1 103.3 20 97.5 54 SG Paving, 46'N by 52'E from NE building corner 1 101.7 19.7 95.9 55 SG Retest for test number 39 report dated 11/20/06 1 LT 94.2 22 97.1 56 SG Retest for test number 38 report dated 11/20/06 1 LT 93.5 21.9 96.4 57 SG Retest for test number 37 report dated 11/20/06 1 LT 95.1 22.2 gg LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. ~~~ FARGtr CONSULTANTR, INC. 11440 Reeder Rd. Dallas, Texas 75229 "1'cl. 214352-4100 hax. 214-352-4811 Puge 2 of 2 REPORT OF FIELD COMPACTION Tested For: Holt Lunsford Commercial Date Performed: 11/27/2006 Project Name: Coppell Trade Center Building D FARGO Project No. M06-1165 Coppell, Texas Density: Per ASTM D-2922 Gauge Manufacturer: Humboldt Moisriue: Per ASTM D-3017 Gauge Model: HS-SOOlEZ Test Mode: Direct Transmission Probe Depth: 8 inches All tests comply with the project requirements, unless otherwise noted Technician: Juan Carlos Espinosa Respectfully Submitted, Distribution: Holt Lansford Commercial -Ken Newman Fargo Consultants, InC. Mcfadden & Miller- Jon Jacobson City ofCoppell -Larry Davis ,:' City ofCoppell -Lee Stone Checked By: LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) [o whom it is addressed and may no[ be reproduced except in full without the written approval of Fargo Consultants, lne.