Coppell Trade 2-LR061114~. l~ _. ] 1440 Reeder Rd. • Dallas, TX 75229 FARGO CONSULTANTS, ixc. Tel. (214) 352-4100 • Fax (214) 352-4811 CONCRETE COMPRESS STRENGTH REPORT CLIENT: Holt Lunsford Commercial Sample Date: 11/14/06 PROJECT: Coppell Trade nter Building D Project No.: M06-1165 Coppell, T as ~ CONCRETE INFORMATION CONTRACTOR: Mcfadden and Miller TICKET NO.: 362556 AMBIENT TEMP.(°F): 54 CONCRETE TEMP.(°F): 70 TIME BATCHED: 7 :19 a.m. TIME SAMPLED: 8:15 a.m. WEATHER CONDITION: Partly Cloudy LOCATION OF PLACEMENT: Paving-approch, CONCRETE SUPPLIER: TXI PLANT/TRUCK: 141 / 68 MIX ID NUMBER: 8205 AIR (%): 4.7 (ASTM C 231) WATER ADDED (gal): 0 SLUMP (inches): 3 1 / 2 (ASTM C 143) 6'S by 9'W from NE building corner CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS DESIGN STRENGTH OF CONCRETE (3500 psil 28 days ) CYLINDER AGE DATE TOTAL LOAD COMPRESSIVE Percent of Design Strength NUMBER ~' (Days) TESTED (pounds) STRENGTH (%) _ si _ 1A 7 _ 11 21 06 _ 113 300 ~ 4010 134 1B _ 28 _12112 06 140L480 _ 4970 L166~ ~ __ 1C _ 28 12 .12 06 143 060 5060___ L 169 ' _ _ 1D Hold _ _ _-__-- I - Cylinders Type: Nominal Cylinder Size 6"X12" (ASTM C 39) Specifications: Making and curing (ASTM C 31) Testing Methods (ASTM C 39) Remarks: Technician: V Robinson Distribution: Holt Lansford Commercial - Ken Newman Mcfadden & Miller - Jon Jacobson City of Coppell - Larry Davis FARGO CONSULTANTS, INC. Checked by: Gary Moor C.E.T. CMT Manager ~Cil~t i~y-~ Geotechnical Engineering f Construction Materials Testing ~ Environmental Services www. dallasfargo. com 11440 Reeder Rd. • Dallas, TX 75229 FAR(30 CONSULTANTS, iNC. Tel. (214) 352-4100 • Fax (214) 352-4811 CONCRETE COMPRESSIVE STRENGTH REPORT CLIENT: Holt Lunsford Commercial Sample Date: 11/14/06 PROJECT: Coppell Trade Center Building D Project No.: M06-1165 Coppell, Texas ~_ CONCRETE INFORMATION CONTRACTOR: Mcfadden and Miller TICKET NO.: 362931 AMBIENT TEMP.(°F): 70 CONCRETE TEMP.(°F): 75 TIME BATCHED: 10:3 0 a . m. TIME SAMPLED: 11 :21 a.m. WEATHER CONDITION: Clear LOCATION OF PLACEMENT: Paving-parking lot, corner CONCRETE SUPPLIER: Txz PLANT/TRUCK:141 / 1115 MIX ID NUMBER: 8205 AIR (%): 4.6 (ASTM C 231) WATER ADDED (gal): 0 SLUMP (inches): 5 (ASTM C 143) 15'N by 300'W from NE building ~ CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS DESIGN STRENGTH OF CONCRETE (3500 psil 28 days ) CYLINDER NUMBER i AGE (Days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH si Percent of Design Strength (%) 2A i 7 11 21 06 114 480 4050 116 __ ~ 2B 28 12 12 06 1431500 5080 _ 145 2C 28 12 12 06 141 280 5000 143 2D Hold Cylinders Type: Nominal Cylinder Size 6"X12" (ASTM C 39) Specifications: Making and curing (ASTM C 31) Testing Methods (ASTM C 39) Remarks: Technician: v Robinson Distribution: Holt Lansford Commercial - Ken Newman Mcfadden & Miller - Jon Jacobson City of Coppell - Larry Davis FARGO CONSULTANTS, INC. Checked by: Gary Moor C.E.T. CMT Manager Geotechnica! Engineering i Construction Materials Testing i Environmental Services www. dagasrargo. com ~ ~~Iw.~. FARGO CONBULTANTB, INC. Report of Reinforcing Steel Observation Tested For: Holt Lunsford Commercial Project Kame: Coppell Trade Center Building D Coppell, Texas 11440 Reeder Rd. • Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Date of Service: 11/14/06 FCI Project No.: M06-1165 Locations and Items Observation: East approach and South parking lot (West portion) /Reinforcing Steel Items Conforming Items Conforming Items Conforming. Ins ected Ins ected Ins ected Column Ties Placing Drawings Yes Bar Length and yes Properly Tied N/A Approved Shape and S aced Bar Size Yes Proper Bar I,eS Stirrup Spacing N/A Placement and T e Bar Grade Yes Properly Tied Yes Lapped Splices Yes Bar Clean Yes Dowel Bars in yes Welded Splices N/A Place Form Clean N/A Proper Bar Yes Mechanical N/A Su orts Splices Number of Bars Yes Proper Cover Yes N/A. Indicates not applicable Remarks: No discrepancies were observed. Technician: Vernon Robinson Distribution: Holt Lansford Commercial -Ken Newman Mcfadden & Miller- Jon Jacobson City of Coppell -Larry Davis Respectfully Submitted, Fargo Consultan nc. Checked by: L]MITATIONS: This n;port presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. Geotechnical Engineering • Constrztctiots Materials Testing • Environmental Services www. dallasfargo. com