Loading...
Coppell Trade 2-LR061113/'1 _ ~"~. FARCSO CONBi~LZ'a~'3'6, INC. 11440. Reeder Rd. • Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 WATER PRESSURE INJECTION OBSERVATION REPORT Client. H~It Lunsford Commercial Project: C,~ppell Trade Center Building D C~ppell, Texas Injection Contractor: Mcfadden & Miller Date of Service: 11/13/06 Project No: M06-1165 Location: Building pad -west half Area injected previously: Approximately 0 square feet of 4th pass Area injected (on this day): Approximately 19,500 square feet of 4th pass Area injected (to date): Approximately 19,500 square feet of 4th pass Gallons oiWater used: 41,000 Surfactant Used: lgallon / 3,500 gallons of water Injection Pressure (psi): 90 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12 Total Depth of Injection (feet): 12 Remarks: Time Start 7:00 a.m. / 2:00 p.m. End 9:30 a.m. / 3:00 p.m. Technician: Gary Moore, C.E.T. Specified Requirements as per manufacturer 50 psi-100psi 5 feet (max.) 12 inches 12 feet Water Meter Reading 9069000 9110600 ~~ if Checked by: °' ~ ~ Distribution: Holt Lansford Commercial -Ken Newman Mcfadden & Miller-Jon Jacobson City of Coppell -Lee Stone LIMITATIONS: "fLis report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to wham it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, lnc. Ceotechnical Engineering • Construction Materials Testing • Environmental Services www. dallasfargo. com