WATER PRESSURE INJECTION
OBSERVATION REPORT
Client: Holt Lunsford Commercial
Project: Coppell Trade Center Building D
Coppell, Texas
Injection Contractor: Mcfadden & Miller
Date of Service: 11 / 10/06
Project No: M06-1165
Location: Building pad -west half
Area injected previously: Approximately 12,000 square feet of 3rd pass
Area injected (on this day): Approximately 21,800 square feet of 3rd pass
Area injected (to date): Approximately 33,800 square feet of 3rd pass
Gallons of Water used: 49,000
Surfactant Used: lgallon / 3,500 gallons of water
Injection Pressure (psi): 90
Injection Probe Spacing (feet): 5
Injected Depth Interval (in.) until refusal: 12
Total Depth of Injection (feet): 12
Remarks:
Time
Start 7:30 a.m. / 2:00 p.m.
End 10:00 a.m. / 3:00 p.m.
Technician: Gary Moore, C.E.T.
Specified Requirements
as per manufacturer
50 psi-100psi
5 feet (max.)
12 inches
12 feet
Water Meter Reading
8945600
8994600
Checked by:
Distribution: Holt Lansford Commercial -Ken Newman
Mcfadden & Miller -Jon Jacobson
City of Coppell -Lee Stone
LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no
responsibility for variation in quality, performance, Feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed
and may not be reproduced except iu full without the written approval of Fargo Co~uultants, Ina