Coppell Trade 2-LR061107/! ~~. f FARt~O CONSiTLTANTB, INC. WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Commercial Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden & Miller 11440 Reeder Rd. • Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 Date of Service: 11/07/06 Project No: M06-1165 Location: Building pad -west half Area injected previously: Approximately 11, 000 square feet of 2nd pass Area injected (on this day): Approximately 16,800 square feet of 2°d pass Area injected (to date): Approximately 27,800 square feet of 2nd pass Gallons of Water used: 68,000 Surfactant Used: lgallon / 3,500 gallons of water Injection Pressure (psi): 80 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 5 Total Depth of Injection (feet): 12 Remarks: Time Start 7:00 a.m. / 2:00 p.m. End 9:00 a.m. / 3:00 p.m. S ecified Requirements as per manufacturer 50 psi-100psi 5 feet (max.) 12 inches 12 feet Water Meter Reading 8819600 8887600 Technician: William Youngstrom Distribution: Holt Lansford Commercial -Ken Newman Mcfadden & Miller- Jon Jacobson City of Coppell -Lee Stone Checked by: LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samp]es selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. Geotechnical Engineering • Construction Materials Testing • Environmental Services www.dallasfargo.com