Coppell Trade 2-LR061103F~,G J FAR GO CONSULTAN'~S, INC. 11440 Reeder Rd. • Dallas, Texas %5229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Commercial Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden & Miller Date of Service: 11/03/06 Project No: M06-1165 Location: Building pad -west half Area injected previously: Approximately 27, 500 square feet of 4th pass Area injected (on this day): Approximately 12,800 square feet of 4th pass Area injected (to date): Approximately 40,500 square feet of 4th pass Gallons of Water used: 63,800 Specified Requirements Surfactant Used: lgallon / 3,500 gallons of water as per manufacturer Injection Pressure (psi): 90 50 psi-100psi Injection Probe Spacing (feet): 5 5 feet (max.) Injected Depth Interval (in.) until refusal: 12 12 inches Total Depth of Injection (feet): 12 12 feet Remarks: Time Water Meter Reading Start 8:00 a.m. / 2:00 p.m. 8623500 End 10:00 a.m. / 3:00 p.m. 8687300 Technician: William Youngstrom Checked by: Distribution: Holt Lansford Commercial -Ken Newman Mcfadden & Miller -Jon Jacobson City of Coppell -Lee Stone LIMITATIONS: This report presents test resu]IS (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, perfonnauce, feature or conditions beyond i[s control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, luc. Geotechnical Engineering ~ Constrcrction Materials Testing • Environmental Services www. dallasfm~go. com ... ,- ~.. ~ „ • • "'~ ~~ 11440 Reeder Rd. • Dallas, TX 75229 Fnx.cso ooxsvzzaNTS, rxQ. Tel. (214) 352-4100 • Fax (2l4) 352-4811 CONCRETE COMPRESSIVE STRENGTH REPORT CLIENT: Holt Lunsford Commercial Sample Date: 11/03/06 PROJECT: Coppell Trade Center Building D Project No.: M06-1165 Coppell, Texas CONCRETE INFORMATION CONTRACTOR: Mcfadden and Miller TICKET NO.: 356673 AMBIENT TEMP.(°F): 47 CONCRETE TEMP.(°F): 66 TIME BATCHED: 7:23 a.m. TIME SAMPLED: 8:07 a.m. WEATHER CONDITION: Partly Cloudy LOCATION OF PLACEMENT: Paving-fire building pad CONCRETE SUPPLIER: Txz PLANT/TRUCK: 141 / 7 0 MIX ID NUMBER: 517 AIR (%): 3 . 8 (ASTM C 231) WATER ADDED (gal): o SLUMP (inches): 5 (ASTM C 143) lane, 110'S by 60'W from SE corner of CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS DESIGN STRENGTH OF CONCRETE (4000 psi/ 28 days ) CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH si Percent of Design Strength (%) 1A 7 11 10 06 107 290 3790 95~ 1B 28 12 1 06 131 030 4630 116 1C 28 12 1 06 132 680 4690 117 1D Hold Cylinders Type: Nominal Cylinder Size 6"X12" (ASTM C 39) Specifications: Making and curing (ASTM C 31) Testing Methods (ASTM C 39) Remarks: Technician: J Solon Distribution: Holt Lansford Commercial - Ken Newman Mcfadden & Miller - Jon Jacobson City of Coppell - Larry Davis FARGO CONSULT TS, INC. Checked by: Gary Moore C.E.T. CMT Manag r Geotechnical Engineering ~ Construction Materials Testing i Environmental Services www.dallasfargo.com ;.... } '... 11440 Reeder Rd. • Dallas, TX 75229 Faxc~o coxsvrxwxTS, irrc. 7e1. (2l4) 352-4100 • Fax (214) 352-4811 CONCRETE COMPRESSIVE STRENGTH REPORT CLIENT: Holt Lunsford Commercial Sample Date: 11/03/06 PROJECT: Coppell Trade Center Building D Project No.: M06-1165 Coppell, Texas CONCRETE INFORMATION CONTRACTOR: Mcfadden and Miller TICKET NO.: 356813 CONCRETE SUPPLIER: Txz AMBIENT TEMP.(°F): 58 PLANT/TRUCK: 141 / 111 CONCRETE TEMP.(°F): 71 MIX ID NUMBER: 517 TIME BATCHED: 9 : 00 a . m. AIR (%): 4.2 (ASTM C 231) TIME SAMPLED: 9 : 54 a.m. WATER ADDED (gal}: 5 WEATHER CONDITION: Partly Cloudy SLUMP (inches): 7 1 /2 (ASTM C 143) LOCATION OF PLACEMENT: Paving, 113 ' S by 97 ' W from SE corner of building pad CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS DESIGN STRENGTH OF CONCRETE (4000 psi/ 28 days ) CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH si Percent of Design Strength (%) 2A 7 11 10 06 101 640 3590 90~ 2B 28 12 1 06 128 710 4550 114 2C 28 12 1 06 129 440 4580 115 2D Hold Cylinders Type: Nominal Cylinder Size 6"X12" (ASTM C 39) Specifications: Making and curing (ASTM C 31) Testing Methods (ASTM C 39) Remarks: Technician: J Solon Distribution: Holt Lansford Commercial - Ken Newman Mcfadden & Miller - Jon Jacobson City of Coppell - Larry Davis FARGO CONSULTA TS, INC. Checked by: Gary Moore, C.E.T. CMT Manager Geotechnical Engineering i Construction Materials Testing i Environmental Services www. dallasfargo. com ;/ ' 11440 Reeder Rd. • Dallas, TX 75229 FAR(30 CONSULTANTS, Ixe. Tel. (214) 352-4100 • Fax (214) 352-4811 CONCRETE COMPRESSIVE STRENGTH REPORT CLIENT: Holt Lunsford Commercial Sample Date: 11/03/06 PROJECT: Coppell Trade Center Building n Project No.: M06-1165 Coppell, Texas CONCRETE INFORMATION CONTRACTOR: Mc f adden and Mi 11 er TICKET NO.: 356966 CONCRETE SUPPLIER: Txz AMBIENT TEMP.(°F): 63 PLANT/TRUCK: 141 / 64 CONCRETE TEMP.(°F): 78 MIX ID NUMBER: 517 TIME BATCHED: 10:27 a.m. AIR(%): 3.9 (ASTMC231) TIME SAMPLED: 11:48 a.m. WATER ADDED (gal}: 5 WEATHER CONDITION: Partly Cloudy SLUMP (inches): 5 (ASTM C 143) LOCATION OF PLACEMENT: Paving, 109 ' S by 187 ' W from SE corner of building pad CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS ~ DESIGN STRENGTH OF CONCRETE (4000 psi/ 28 days ) CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH si Percent of Design Strength (%) 3A 7 11 10 06 101 430 3590 90~ 3B 28 12 1 06 129 110 4570 114 3C 28 12 1 06 128 060 4530 113 3D Hold Cylinders Type: Nominal Cylinder Size 6"X12" (ASTM C 39} Specifications: Making and curing (ASTM C 31) Testing Methods (ASTM C 39) Remarks: Technician: J Solon Distribution: Holt Lansford Commercial - Ken Newman Mcfadden & Miller - Jon Jacobson City of Coppell -Larry Davis FARGO CONSULT TS, INC. Checked by: Gary Moore C.E.T. CMT Manager Geotechnica! Engineering i Construction Materials Testing i Environmental Services www.dallasfargo.com _:._. Y.... `'j 11440 Reeder Rd. • Dallas, TX 75229 _-_ __ FAR.CiO CON6ULTANT6, IxC. Tel. (214) 352-4100 • Fax (214) 352-481 l CONCRETE COMPRESSIVE STRENGTH REPORT CLIENT: Holt Lunsford Commercial Sample Date: 11/03/06 PROJECT: Coppell Trade Center Building D Project No.: M06-1165 Coppell, Texas CONCRETE INFORMATION CONTRACTOR: Mcfadden and Miller TICKET NO.: 357046 CONCRETE SUPPLIER: TXI AMBIENT TEMP.(°F): 68 PLANT/TRUCK: 141 / 112 CONCRETE TEMP.(°F): 82 MIX ID NUMBER: 517 TIME BATCHED: 11:10 a. m. AIR (%): 4.1 (ASTM C 231) TIME SAMPLED: 1 :14 p . m. WATER ADDED (gal): 0 WEATHER CONDITION: Partly Cloudy SLUMP (inches): 4 3 /4 (ASTM C 743) LOCATION OF PLACEMENT: Paving, 110' S by 254'W from SE corner of building pad CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS DESIGN STRENGTH OF CONCRETE (4000 psi! 28 days ) CYLINDER NUMBER AGE (Days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH si Percent of Design Strength (%) 4A 7 11 10 06 104 010 3680 92~ 4B 28 12 1 06 135 110 4780 120 4C 28 12 1 06 133 620 4730 118 4D Hold Cylinders Type: Nominal Cylinder Size 6"X12" (ASTM C 39) Specifications: Making and curing (ASTM C 31) Testing Methods (ASTM C 39) Remarks: Technician: s Solon Distribution: Holt Lansford Commercial - Ken Newman Mcfadden & Miller - Jon Jacobson City of Coppell - Larry Davis FARGO CONSULTANTS, INC. Checked by: Gary Moore, C.E.T. CMT Manager Geotechnical Engineering i Construction Materials Testing i Environmental Services www.dallasfargo.com F' - C,~.. FA.rtGO CONSULTANTS, INC. Report of Reinforcing Steel Observation Tested For: Holt Lunsford Commercial Project Name: Coppell Trade Center Building D Coppell, Texas 11440 Reeder Rd. • Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Date of Service: 11/03/06 FCI Project No.: M06-1165 Locations and Items Observation: Parking lot and Drive, east portion south of proposed building /Reinforcing Steel Items Conforming Items Conforming Items Conforming Ins ected Ins ected Ins ected Column Ties Placing Drawings Yes Bar Length and Yes Properly Tied N/A Approved Shape and S aced Bar Size Yes Proper Bar I,eS Stirrup Spacing N/A Placement and T e Bar Grade Yes Properly Tied Yes Lapped Splices Yes Bar Clean Yes Dowel Bars in yes Welded Splices N/A Place Form Clean N/A Proper Bar Yes Mechanical N/A Su orts Slices Number of Bars Yes Proper Cover Yes N/A: Indicates not applicable Remarks: No discrepancies were observed. Technician: Joshua Solon Distribution: Holt Lansford Commercial -Ken Newman Mcfadden & Miller- Jon Jacobson City of Coppell -Lee Stone Respectfully Submitted, Fargo Consultan ,Inc. Checked by: LIMITATIONS: T7iis report presents test results (a[ particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, [nc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. Geotechnical Engineering • Construction Materials Testing • Environmental Services www. dallasfargo. com