FARQO CONSVLTANTa, INC.
WATER PRESSURE INJECTION
OBSERVATION REPORT
Client: Holt Lunsford Commercial
Project: Coppell Trade Center Building D
Coppell, Texas
Injection Contractor: Mcfadden & Miller
11440 Reeder Rd. • Dallas, Texas 75229
Tel. 214-352-4100 Fax. 214-352-4811
Page 1 of 1
Date of Service: 10/25/06
Project No: M06-1165
Location: Building pad, east half
Area injected previously: Approximately 45,500 square feet of 3rd pass
Area injected (on this day): Approximately 13,500 square feet of 3`d pass
Area injected (to date): Approximately 59,000 square feet of 3rd pass
Gallons of Water used: 51,000
Surfactant Used: lgallon / 3,500 gallons of water
Injection Pressure (psi): 80
Injection Probe Spacing (feet): 5
Injected Depth Interval (in.) until refusal: 12-18
Total Depth of Injection (feet): 12
Remarks:
Time
Start 8:00 a.m. / 1:30 p.m.
End 10:00 a.m. / 3:00 p.m.
Technician: Joshua Solon
Specified Requirements
as per manufacturer
50 psi-100psi
5 feet (max.)
12 inches
12 feet
Water Meter Reading
8168700
8219700
Distribution: Holt Lansford Commercial -Ken Newman
Mcfadden & Miller -Jon Jacobson
City of Coppell -Lee Stone
Checked by:
LIMITATIONS: This repoR presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no
responsibility for variation in quality, performance, feature or conditions beyond its control. This repoR is for the exclusive use of the person(s) to whom it is addressed
and may not be reproduced except in full without the written approval of Fargo Consultants, Inc.