Loading...
Coppell Trade 2-LR061021/ ,. _. FARCSO CONHUZTANTS, INC. WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lansford Commercial Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden & Miller 11440 Reeder Rd. • Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 Date of Service: 10/21 /06 Project No: M06-1165 Location: Building pad, east half 3` pass Area injected previously: Approximately 7,700 square feet of 3`~ pass Area injected (on this day): Approximately 13,500 square feet of 3`d pass Area injected (to date): Approximately 21,200 square feet of 3`d pass Gallons of Water used: 51,000 Surfactant Used: lgallon / 3,500 gallons of water Injection Pressure (psi): 100 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12-18 Total Depth of Injection (feet): 12 Remarks Time Start 8:00 a.m. / 1:30 p.m. End 10:00 a.m. / 3:00 p.m. Saecified Requirements as per manufacturer 50 psi-100psi 5 feet (max.) 12 inches 12 feet Water Meter Reading 8011200 8062200 Technician: Joshua Solon Distribution: Holt Lansford Commercial -Ken Newman Mcfadden & Miller -Jon Jacobson City of Coppell -Lee Stone Checked by: LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, [nc. Geotechnical Engineering • Construction Materials Testing • Environmental Services wtvw.dallasfargo. com