Gateway BP(1.4)-LR061214CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061357.0014 Service Date: December 6, 2006 Client: Hill Wilkinson LTD Attn: Gene Fort 800 Klein Rd Ste 100 Plano TX 75074 Material Information Specified Strength: 3000 psi 28 Days Batch Time: 3:09am Plant: 7 Supplier: Lattimore Materials Co. Truck No: 947 Ticket No: 7373839 Mix I.D. No.: 1261 Water Added Onsite Before Test: 10Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, Concrete Temperature, °F: Ambient Temperature, °F: Plastic Unit Weight, pcf: Laboratory Test Data Set No. 1 1 1 Result 5.00 5.0 55 42 Specimen Diameter Area ID (inches) (sq. inches) 1 6.00 28.27 2 3 iz eg Specification Report Date: Dece 4806 Project: averty Pavement Expansion 770 Gateway Blvd. PO #14 -2155 Coppell, TX Project No.: 94061357 Sample Information Date Cast: December 6, 2006 Sampled by: Jesus Rojas Weather Conditions: Clear Accumulative Yards: 80/700 Placement Method: Pump Sample Locations: Set #1, see attached sketch Placement Location: Pavement, see attached sketch Date Tested 12/13/2006 01/03/2007 01/03/2007 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 lierracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Time: 3:45am Age at Maximum Compressive Test Load S (days) (Ibs) 7 118,290 28 28 Comments: Not tested for plastic unit weight. Services Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of.the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 7 O1- SKS/R01- FUlure Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061357.0014 Service Date: December 6, 2006 Client: Hill Wilkinson LTD Attn: Gene Fort 800 Klein Rd Ste 100 Plano TX 75074 Material Information Specified Strength: 3000 psi 28 Days Batch Time: 4:11 am Plant: 7 Supplier: Lattimore Materials Co. Truck No: 959 Ticket No: 7173847 Mix I.D. No.: 1261 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, Concrete Temperature, OF Ambient Temperature, °F: Plastic Unit Weight, pcf: Laboratory Test Data Set No. 2 2 2 Result 6.00 6.0 55 48 Specimen Diameter Area ID (inches) (sq. inches) 1 6.00 28.27 2 3 Specification Report Date: December 14, 2006 Project: Haverty Pavement Expansion 770 Gateway Blvd. PO #14 -2155 Coppell, TX Project No.: 94061357 lierracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Sample Information Date Cast: December 6, 2006 Sampled by: Jesus Rojas Weather Conditions: Clear Accumulative Yards: 160/700 Placement Method: Pump Sample Locations: Set #2, see attached sketch Placement Location: Pavement, see attached sketch Comments: Not tested for plastic unit weight. Services Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 7 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Time: 4:45am Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 12/13/2006 7 75,190 2,660 01/03/2007 28 01/03/2007 28 01- SKSfRO1 -FUure Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061357.0014 Service Date: December 6, 2006 Client: Hill Wilkinson LTD Attn: Gene Fort 800 Klein Rd Ste 100 Plano TX 75074 Material Information Specified Strength: 3000 psi 28 Days Batch Time: 6:01 am Plant: 7 Supplier: Lattimore Materials Co. Truck No: 7059 Ticket No: 629556 Mix I.D. No.: 1261 Water Added Onsite Before Test: OGallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, Concrete Temperature, oF: Ambient Temperature, oF: Plastic Unit Weight, pcf: Result 6.00 8.0 53 43 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 3 1 6.00 28.27 3 2 3 3 MARGINAL 7 -DAY STRENGTH RESULTS Specification Report Date: December 14, 2006 Project: Haverty Pavement Expansion 770 Gateway Blvd. PO #14 -2155 Coppell, TX Project No.: 94061357 Sample Information Date Cast: December 6, 2006 Sampled by: Jesus Rojas Weather Conditions: Clear Accumulative Yards: 300/700 Placement Method: Pump Sample Locations: Set #3, see attached sketch Placement Location: Pavement, see attached sketch Comments: Not tested for plastic unit weight. Services Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 7 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 lierracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Time: 6:30am Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/13/2006 7 57,570 2,040 01/03/2007 28 01/03/2007 28 01- 5KS/R01- Future Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061357.0014 Service Date: December 6, 2006 Client: Hill Wilkinson LTD Attn: Gene Fort 800 Klein Rd Ste 100 Plano TX 75074 Material Information Specified Strength: 3000 psi c@ 28 Days Batch Time: 6:48am Plant: 7 Supplier: Lattimore Materials Co. Truck No: 7070 Ticket No: 6295570 Mix I.D. No.: 1261 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, Concrete Temperature, oF: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 6.50 6.0 53 43 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 4 1 6.00 28.27 4 2 4 3 Specification Report Date: December 14, 2006 Project: Haverty Pavement Expansion 770 Gateway Blvd. PO #14 -2155 Coppell, TX Project No.: 94061357 Sample Information Date Cast: December 6, 2006 Sampled by: Jesus Rojas Weather Conditions: Clear, sunny Accumulative Yards: 370/700 Placement Method: Pump Sample Locations: Set #4, see attached sketch Placement Location: Pavement, see attached sketch Comments: Not tested for plastic unit weight. Services Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 7 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 lferracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Time: 7:30am Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/13/2006 7 50,690 1,790 01/03/2007 28 01/03/2007 28 01- SKSIRO1 -Future Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061357.0014 Service Date: December 6, 2006 Client: Hill Wilkinson LTD Attn: Gene Fort 800 Klein Rd Ste 100 Plano TX 75074 Material Information Specified Strength: 3000 psi 28 Days Batch Time: 7:29am Plant: 7 Supplier: Lattimore Materials Co. Truck No: 7024 Ticket No: 7173866 Mix I.D. No.: 1261 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 10 Gallons Field Test Data Test Slump, inches: Air Content, Concrete Temperature, OF Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 5.50 5.9 57 50 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 5 1 6.00 28.27 5 2 5 3 Specification Page 5 of 7 Report Date: December 14, 2006 Project: Haverty Pavement Expansion 770 Gateway Blvd. PO #14 -2155 Coppell, TX Project No.: 94061357 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 lierracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Sample Information Date Cast: December 6, 2006 Sampled by: Jesus Rojas Weather Conditions: Clear, sunny Accumulative Yards: 490/700 Placement Method: Pump Sample Locations: Set #5, see attached sketch Placement Location: Pavement, see attached sketch Time: 8:OOam Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 12/13/2006 7 88,030 3,110 01/03/2007 28 01/03/2007 28 Comments: Not tested for plastic unit weight. Services Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. O1.SKS/RO1 -FNUre Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061357.0014 Service Date: December 6, 2006 Client: Hill Wilkinson LTD Attn: Gene Fort 800 Klein Rd Ste 100 Plano TX 75074 Material Information Specified Strength: 3000 psi 28 Days Batch Time: 8:33am Plant: 7 Supplier: Lattimore Materials Co. Truck No: 7059 Ticket No: 7173877 Mix I.D. No.: 1261 Water Added Onsite Before Test: O Gallons Water Added Onsite After Test: 10 Gallons Field Test Data Test Slump, inches: Air Content, °Ao: Concrete Temperature, °F: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 5.50 5.5 58 55 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 6 1 6.00 28.27 6 2 6 3 Specification Report Date: December 14, 2006 Project: Haverty Pavement Expansion 770 Gateway Blvd. PO #14 -2155 Coppell, TX Project No.: 94061357 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Sample Information Date Cast: December 6, 2006 Sampled by: Jesus Rojas Weather Conditions: Clear, sunny Accumulative Yards: 580/700 Placement Method: Pump Sample Locations: Set #6, see attached sektch Placement Location: Pavement, see attached sketch Date Tested 12/13/2006 01/03/2007 01/03/2007 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Time: 9:OOam Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 89,570 3,170 28 28 Comments: Not tested for plastic unit weight. Services Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 7 01- SKS/R01- Future Hey CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061357.0014 Service Date: December 6, 2006 Client: Hill Wilkinson LTD Attn: Gene Fort 800 Klein Rd Ste 100 Plano TX 75074 Material Information Specified Strength: 3000 psi 28 Days Batch Time: 9:06am Plant: 7 Supplier: Lattimore Materials Co. Truck No: 7021 Ticket No: 7173882 Mix I.D. No.: 1261 Water Added Onsite Before Test: 10 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, Concrete Temperature, 0F: Ambient Temperature,oF: Plastic Unit Weight, pcf: Laboratory Test Data Set No. 7 7 7 Specimen Diameter Area ID (inches) (sq. inches) 1 6.00 28.27 2 3 Terracon Rep: Jesus Rojas Report Distribution: (1) Hill 8 Wilkinson LTD (1) Halff Assoc Inc (1) City of Coppell TX (1) Haverty Furniture Co Inc Result 6.50 5.5 58 55 Report Date: December 14, 2006 Project: Haverty Pavement Expansion 770 Gateway Blvd. PO #14 -2155 Coppell, TX Project No.: 94061357 lierracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Sample Information Date Cast: December 6, 2006 Sampled by: Jesus Rojas Weather Conditions: Clear, sunny Accumulative Yards: 650/700 Placement Method: Pump Sample Locations: Set #7, see attached sketch Placement Location: Pavement, see attached sketch Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 12/13/2006 7 60,790 2,150 01/03/2007 28 01/03/2007 28 Time: 10:10am Comments: Not tested for plastic unit weight. Services Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Reviewed by: Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 7 of 7 01- SKS/R01 -F, se Key r''' r-% „J i REMOVE C CONNECT TO EXIST. CONCRETI a ,.Z 0 0 (If 0 0 Z 1. .1 3 AT JOINT BETWEEN EXISTING PAVEMENT AND NEW PAVEMENT. Terracon Report No. 94061357.0014 Dated 12/06/2006 (Haverty Pavement Expansion) TERRACON REPORT NO. 4'/5? 0c!9 12- 06- Oa INSTALL 372 OF 6" CURB