Coppell Trade 2-LR061102 (2)~; o. b'Ii1iG0 CON 3ULTANTS, INC. 11440 Reeder Rd. • Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Pagelofl WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Commercial Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden & Miller Date of Service: 11/02/06 Project No: M06-1165 Location: Building pad -east half Area injected previously: Approximately 11, 500 square feet of 4th pass Area injected (on this day): Approximately 16,000 square feet of 4th pass Area injected (to date): Approximately 27,500 square feet of 4th pass Gallons of Water used: 65,000 Specified Requirements Surfactant Used: /gallon / 3,500 gallons of water as per manufacturer Injection Pressure (psi): 80 50 psi-100psi Injection Probe Spacing (feet): 5 5 feet (max.) Injected Depth Interval (in.) until refusal: 12 12 inches Total Depth of Injection (feet): 12 12 feet Remarks: Time Water Meter Reading Start 7:30 a.m. / 2:00 p.m. 8558500 End 9:00 a.m. / 3:00 p.m. 8623500 Technician: William Youngstrom Checked by: Distribution: Holt Lansford Commercial -Ken Newman Mcfadden & Miller -Jon Jacobson City of Coppell -Lee Stone LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is far die exclusive use of the person(s) [o whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. Geotechnical Engineering • Consbz~ction Materials Testing • Environmental Services www. dallasfargo. com