Town Center L1B2-LR 990629IN -PLACE DENSITY TESTING fBC ENGINF.ERI1vG, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06/18/1999 Client No.: 26295000 Client: Ewing Prop erties, Inc. Attn: Mark Moms 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Services: In -place density testing. Report No.: 9916825 Report Date 06/29/1999 Project No.: 94991134 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas PROJECT DATA CONTRACTOR Hill & Wilkinson MOISTURE DENSITY RELATIONS: M/D No. 1 Description Brn, yellow, & red sandy clay Laboratory Test Method: ASTM D -698 Field Test Method: Maximum Moisture % Density pcf 13.5 115.0 FIELD DENSITY TESTS ASTM D -2922 ASTM D -2922 Project Requirements Moisture Density -1/ +3% 95% TEST MID MOISTURE DRY DENSITY DENSITY NO TEST LOCATION No. ( %) (pct) (% max) 8" Water Line, W Line 95 35' south of vault, @ grade 1 12.6 109.8 96 96 35' south of vault, 1.5' below grade 1 14.4 110.7 96 97 35' south of vault, @ grade 1 15.8 109.3 95 98 35' south of vault, 1' below grade 1 15.0 111.9 97 Test results on this report meet project specification. Technician: Phil Green � E i ing, Inc. Report Distribution: (1) Ewing Properties, Inc. (1) Raymond L. Goodson, Jr. Engrs. (1) S.0 Companies (1) Hill & Wilkinson, Inc. Paul D. Smith, P.E. (1) Tom Thumb Stores Division (1) City of Coppell - Engr. Dept. Senior Project Engineer (1) Michael F. Twichell, Inc. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc 07TM(D Page I of 1 CONCRETE COMPRESSIVE STRENGTH TEST fW M INC. 8901 Carpenter Frwy., Suite 0100 Dallas, Texas 75247 Report No.: 9916748 Report Date Date of Service: 06/18/1999 p 06/29/1999 Client No.: 26295000 Client: Ewing Properties, Inc. Attn: Mark Moms 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Project No.: 94991134 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hill & W CONCRETE SUPPLIER Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUMP: 3 - 5 " AIR: N/A TEST METHOD: ASTM C -143 5.50 ASTM C -172 7 ASTM C -39 SAMPLE LOCATION: See placement location CYLINDER MARKED SET NO. 1 1 1 2 1 3 1 4 CONCRETE CLASS 163 PLACEMENT DATE 06/18/1999 BATCH TIME: 4: loam TIME SAMPLED 4:50am BY: Jimmy Atnip WEATHER CONDITIONS: Clear TEMPERATURE M - AIR 69 F CONCRETE: 78 F TRUCK NO: 785 TICKET NO: 7072757 AIR CONTENT (%): N/A UNIT wEIGHT (pcf): N/A PLACEMENT LOCATION: Paving- west side of Tom Thumb (See attached sketch) REPORT OF TESTS ACCUMULATIVE YARDS 80 MEASURED MAXIMUM COMPRESSIVE SLUMP DATE AGE LOAD STRENGTH (ink) TESTED (days) (lbs. force) (psi) 5.50 06/25/1999 7 128420 4540 5.50 06/25/1999 7 130890 4630 Average 4590 5.50 07/16/1999 28 5.50 07/16/1999 28 Placement made with pump, sample taken from mixer. FRACTURE TYPE J� This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. OILL Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST fBC ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report No.: 9916748 Report Date Date of Service: 06 /18/1999 p 06/29/1999 Client No.: 26295000 Client: Ewing Properties, Inc. Attn: Mark Morris 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Project No.: 94991134 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hill & Wilkinson CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUMP: 3 -5" AIR: N/A TEST METHOD: ASTM C -143 (days) ASTM C -172 (psi) ASTM C -39 SAMPLE LOCATION: See page 1 CONCRETE CLASS: 163 PLACEMENT DATE: 06 /18/1999 BATCH TIME: 5:17am TIME SAMPLED: 5:45am BY: Jimmy Atnip WEATHER CONDITIONS: Overcast TEMPERATURE (F) - AIR 65 F CONCRETE: 79 F TRUCK NO: 616 TICKET NO: 7072768 AIR CONTENT M: N/A UNIT WEIGHT (pd): N/A PLACEMENT LOCATION: See page 1 REPORT OF TESTS ACCUMULATIVE YARDS: 190 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH SET NO. (inches) TESTED (days) (lbs. force) (psi) 2 1 5.25 06/25/1999 7 111210 3930 2 2 5.25 06/25/1999 7 113080 4000 Average 3970 2 3 5.25 07/16/1999 28 2 4 5.25 07/1611999 28 Placement made with pump, sample taken from mixer. FRACTURE TYPE k" This report is exclusively for the use of the client indicated above and shall not be reproduced except in fall without the written approval of HBC Engineering, loc. O1LL Page 2 of 4 CONCRETE COMPRESSIVE STRENGTH TEST fBC ENGIlVEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06 /18/1999 Report No.: 9916748 Report Date 06/29/1999 Client No.: 26295000 Client: Ewing Properties, Inc. Attn: Mark Moms 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Project No.: 94991134 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hill & Wilkinson CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUMP: 3 - 5 " AIR: N/A TEST METHOD: ASTM C -143 (inches) ASTM C -172 (days) ASTM C -39 SAMPLE LOCATION: See page 1 CONCRETE CLASS: 163 PLACEMENT DATE: 06/18/1999 BATCH T wE: 6:08am TIME SAMPLED: 6:36am BY: Jimmy Atnip WEATHER CONDITIONS: Overcast TEMPERATURE (F) - AIR 65 F CONCRETE: 78 F TRUCK NO: 757 TICKET NO: 7072775 AIR CONTENT (%): N/A UNIT WEIGHT (pcf): N/A PLACEMENT LOCATION: See page 1 Placement made with pump, sample taken from mixer. ACCUMULATIVE YARDS: 260 COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 3800 3920 3860 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. SILL Page 3 of 4 REPORT OF TESTS CYLINDER MEASURED MAXIMUM MARKED SLUMP DATE AGE LOAD SET NO. (inches) TESTED (days) (tbs. force) 3 1 5.50 06/2511999 7 107450 3 2 5.50 06/25/1999 7 110750 Average 3 3 5.50 07/16/1999 28 3 4 5.50 07/16/1999 28 Placement made with pump, sample taken from mixer. ACCUMULATIVE YARDS: 260 COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 3800 3920 3860 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. SILL Page 3 of 4 CONCRETE COMPRESSIVE STRENGTH TEST fDC EN K 11 EERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06 /18/1999 Report No.: 9916748 Report Date 06/29/1999 Client No.: 26295000 Client: Ewing Properties, Inc. Attn: Mark Morris 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Project No.: 94991134 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hill & Wilkinson CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUM: 3 -5" AIR: N/A TEST METHOD: ASTM C -143 6.00 ASTM C -172 7 ASTM C -39 SAMPLE LOCATION: See page I CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 4 1 6.00 4 2 6.00 4 3 6.00 4 4 6.00 CONCRETE CLASS: 163 PLACEMENT DATE: 06/18/1999 BATCH TD4E: 8:30am TIME SAMPLED: 9:00am BY: Jimmy Atnip WEATHER CONDITIONS: Clear TEMPERATURE (F) - AIR 75 F CONCRETE: 79 F TRUCK NO: 611 TICKET NO: 7072791 AIR CONTENT (%): N/A UNIT WEIGHT (pd): N/A PLACEMENT LOCATION: See page 1 REPORT OF TESTS ACCUMULATIVE YARDS: 350 Placement made with pump, sample taken from mixer. FRACTURE TYPE Technician: Jimmy Atnip Started: 4:00am Finished: 7:00am 11J1.. Engineer' Report Distribution: (1) Ewing Properties, Inc. (1) Raymond L. Goodson, Jr. Engrs. (1) S.0 Companies (1) Hill & wilUnson, Inc. Eugene H hour (1) Tom numb Stores Division (1) City of Coppell - Engr. Dept_ Vice President (1) Michael F. Twichell, Inc This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. O1LL Page 4 of 4 MAXIMUM COMPRESSIVE DATE AGE LOAD STRENGTH TESTED (days) (Ibs. force) (psi) 06/25/1999 7 91710 3240 06/25/1999 7 93850 3320 Average 3280 07/16/1999 28 07/16/1999 28 Placement made with pump, sample taken from mixer. FRACTURE TYPE Technician: Jimmy Atnip Started: 4:00am Finished: 7:00am 11J1.. Engineer' Report Distribution: (1) Ewing Properties, Inc. (1) Raymond L. Goodson, Jr. Engrs. (1) S.0 Companies (1) Hill & wilUnson, Inc. Eugene H hour (1) Tom numb Stores Division (1) City of Coppell - Engr. Dept_ Vice President (1) Michael F. Twichell, Inc This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. O1LL Page 4 of 4 CN 10. W c; 0: fl 0 OD 0 30*X 30' ACCESS ESM*T. 142 T - - - - -- — -- ------ - - - - -- — — — — — — — — — 9 1.5.: 4. 4 Z M OS Ic, 21A 1• S 1 t 0 wr\ T 041 *** IL K -T J. Ln (YA t 2 cr 3f 125 5� as — -a- - - Vni V), u '4 V 2 �%4 w I Tt 00 •7� ' \ ' \, "�_ \ � �. Z ' I \— a-- -� -a . �— \ +. -_�— a 1•as•a• ( Lo LP 0 2070 f -A. 1 4 , % .. ..... ..... xm.