Loading...
Town Center L1 B2-LR 990622IN -PLACE DENSITY TESTING fDC ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06/11/1999 Report No.: 9916136 Report Date Client No.: 26295000 Client: Ewing Properties, Inc. Attn: Mark Morris 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Services: CONTRACTOR: Hill & Wilkinson Project No.: 94991134 06/22/1999 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas PROJECT DATA Laboratory Test Method: ASTM D -698 Field Test Method: ASTM D -2922 ASTM D -3017 MOISTURE DENSITY RELATIONS: M/D No. Description Maximum Project Requirements Moisture % Density pcf Moisture Density 1 Red/brown clay 19.0 104.5 -1 / +3% 95% FIELD DENSITY TESTS TEST M/D MOISTURE DRY DENSITY DENSITY NO TEST LOCATION No. ( %) (pcf) (% max) 91 Backfill existing manhole, 1st lift 1 21.4 92 Backfill existing man hole, 2nd lift 1 20.2 Test results on this report meet project specification. 100.4 96 101.0 97 Technician: Roy Montgomery � En in Ing, Inc. Report Distribution: (1) Ewing Properties, Inc. (1) Raymond L. Goodson, Jr. Engrs. (1) S.0 Companies (1) Hill & Wilkinson, Inc. Paul D. Smith, P.E. (1) Tom Thumb Stores Division (1) City of Coppell - Engr. Dept. Senior Project Engineer (1) Michael F. Twichell, Inc. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc 07TMP Page I of I CONCRETE COMPRESSIVE STRENGTH TEST fBC ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06 /09/1999 Client No.: 26295000 Client: Ewing Properties, Inc. Attn: Mark Morris 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Report No.: 9915823 Report Date 06/22/1999 Project No.: 94991134 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hill & Wilkinson CONCRETE SUPPLIER: Lattimore PLANT: 3 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUMP: 3 -5" AIR: 3 -6% TEST METHOD: ASTM C -143 ASTM C -172 ASTM C -39 SAMPLE LOCATION: See placement location CYLINDER MARKED SET 1 1 1 1 NO. CONCRETE CLASS: 163 PLACEMENT DATE: 06/09/1999 BATCH TIME: 3:37am TIME SAMPLED: 4:10am BY: Lee Savage WEATHER CONDITIONS: Warm TEMPERATURE (F) - AIR 78 F CONCRETE: 95 F TRUCK NO: 734 TICKET NO: 3085368 AIR CONTENT (%): 2.6 UNIT WEIGHT (pcf): N/A PLACEMENT LOCATION: Paving -20' south, 100' east of northwest comer of paving REPORT OF TESTS MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lbs. force) ACCUMULATIVE YARDS: 10 COMPRESSIVE STRENGTH FRACTURE (psi) TYPE 1 7.00 06/16/1999 7 130970 4630 2 7.00 06/16/1999 7 121260 4290 Average 4460 3 7.00 07/07/1999 28 4 7.00 07/07/1999 28 Contractor was advised of low air and high slump This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. GILL Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST fBC EN' I , INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06 /09/1999 Client No.: 26295000 Client: Ewing Properties, Inc. Attn: Mark Morris 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Report No.: 9915823 Report Date 06/22/1999 Project No.: 94991134 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hill & Wilkinson CONCRETE SUPPLIER: Lattimore PLANT: 3 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUM: 3 - 5 " AIR: 3 -6% TEST METHOD: ASTM C -143 (days) ASTM C -172 (psi) ASTM C -39 SAMPLE LOCATION: See placement location CONCRETE CLASS: 163 PLACEMENT DATE: 06/09/1999 BATCH TIME: 4:35am TIME SAMPLED: 5:15am BY: Lee Savage WEATHER CONDITIONS: Warm TEMPERATURE (F) - AIR 79 F CONCRETE: 92 F TRUCK NO: 975 TICKET NO: 3085380 AIR CONTENT (%): 2.2 UNIT wEIGHT (pcf): N/A PLACEMENT LOCATION: Paving- 5' south, 5' east of northwest corner of paving REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH SET NO. (inches) TESTED (days) (lbs force) (psi) 2 1 6.00 06/16/1999 7 103870 3670 2 2 6.00 06/16/1999 7 104880 3710 Average 3690 2 3 6.00 07/07/1999 28 2 4 6.00 07/07/1999 28 FRACTURE TYPE This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. OILL Page 2 of 4 CONCRETE COMPRESSIVE STRENGTH TEST fDC ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06 /09/1999 Report No.: 9915823 Report Date 06/22/1999 Client No.: 26295000 Project No.: 94991134 Client: Ewing Properties, Inc. Attn: Mark Morris 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hill & Wilkinson CONCRETE SUPPLIER: Lattimore PLANT: 3 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUMP: 3 -5" AIR: 3 -6% TEST METHOD: ASTM C -143 ASTM C -172 3330 ASTM C -39 SAMPLE LOCATION: See placement location CONCRETE CLASS: 163 PLACEMENT DATE: 06/09/1999 BATCH TD4E: 7:09am TIME SAMPLED: 7:30am BY: Lee Savage WEATHER CONDITIONS: Warm, breezy TEMPERATURE (F) - AIR 80 F CONCRETE: 91 F TRUCK NO: 975 TICKET NO: 3085405 AIR CONTENT (%): 2.6 UNIT WEIGHT (pcf): N/A PLACEMENT LOCATION: Paving- 100' south, 60' east of northwest corner of paving REPORT OF TESTS CYLINDER MARKED SET NO. 3 3 3 3 MEASURED SLUMP DATE (inches) TESTED 1 7.00 06/16/1999 2 7.00 06/16/1999 3 7.00 07/07/1999 4 7.00 07/07/1999 ACCUMULATIVE YARDS: 10 FRACTURE TYPE This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 3 of 4 MAXIMUM COMPRESSIVE AGE LOAD STRENGTH (days) (lbs force) (psi) 7 90730 3210 7 97240 3440 Average 3330 28 28 FRACTURE TYPE This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 3 of 4 CONCRETE COMPRESSIVE STRENGTH TEST f 19C 1 - 1 11 M. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06/09/1999 Report No.: 9915823 Report Date 06/22/1999 Client No.: 26295000 Client: Ewing Properties, Inc. Attn: Mark Morris 14990 Landmark Blvd, #300 Dallas TX 75240 -6729 Project No.: 94991134 Project: Tom Thumb Denton Tap & Sandy Lake Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hill & Wilkinson CONCRETE SUPPLIER: Lattimore PLANT: 3 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi C 28 Days SLUMP: 3 - 5 t1 AIR: 3 -6% TMMETHOD: ASTM C -143 ASTM C -172 ASTM C -39 SAMPLE LOCATION: CYLINDER MARKED SET 4 4 4 4 NO. See placement location MEASURED SLUMP DATE (inches) TESTED CONCRETE CLASS: 163 PLACEMENT DATE: 06/09/1999 BATCH TIME: 8:40am TIME SAMPLED: 9:15am BY: Lee Savage WEATHER CONDITIONS: Warm TEMPERATURE (F) - AIR 84 F CONCRETE: 94 F TRUCK NO: 820 TICKET NO: 3085414 AIR CONTENT (%): 2.4 UNIT WEIGHT (pd): N/A PLACEMENT LOCATION: Paving- 100' South, 120' east of northwest comer of paving REPORT OF TESTS AGE (days) 1 5.00 06/16/1999 7 104970 2 5.00 06/16/1999 7 113080 Average 3 5.00 07/07/1999 28 4 5.00 07/07/1999 28 Technician: Lee Savage MAxnKUM LOAD (lbs. force) Report Distribution: (1) Ewing Properties, Inc. (1) S.0 Companies (1) Tom Thumb Stores Division (1) Michael F. Twichell, Inc. Started: 3:00am Finished: 11:00am (1) Raymond L. Goodson, Jr. Engrs. (1) Hill & Wilkinson, Inc. (1) City of Coppell - Engr. Dept. Eugene Harbour Vice President This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. ACCUMULATIVE YARDS: 10 COMPRESSIVE STRENGTH (psi) 3710 4000 3860 FRACTURE TYPE E 'leering, Inc. OILL Page 4 of 4