SC-Coppell MSN-LR 980714FUGRO SOUTH, INC. � IGRO - ii ■ 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT Coppell ISD Report Date July 14, 1998 PROJECT Coppell Middle School North Sitework Coppell, Texas Project No .: 0771 -2094 SAMPLE DATE: June 11, 't998 CONCRETE CYLINDER COMPRESSIVE STRENGTH.TESTS K. A. Sparks CONTRACTOR: TICKET NO.: CONCRETE SUPPLIER: AMBIENT TEMP. ( °F): PLANT/TRUCK: CONCRETE TEMP. ( °F) (ASTM C- 1064) MIX ID NUMBER: TIME BATCHED: AIR ( % ) (ASTM C -231) : TIME SAMPLED: WATER ADDED (gal): WEATHER CONDITION: SLUMP (in .) (ASTM C -143) : LOCATION OF PLACEMENT: Tennis Court, northeast comer CONCRETE CYLINDER COMPRESSIVE STRENGTH.TESTS Standard 6" x 12 ", 28.27 squarw inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CNS 262 7 06/18/98 62000 2193 3000/28 days CNS 263 28 07/09/98 89000 3148 CNS 264 28 07/09/98 92000 3254 CNS 265 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C 43, Types of ® ® C D : Curing: Methods: ASTM C -39 Fracture: A B REMARKS: Technician: Scott Rogers FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore FUGRO SOUTH, INC. �GRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT Coppell ISD Report Date July 14, 1998 PROJECT Coppell Middle School North Sitework Coppell, Texas Project No .: 0771 -2094 SAMPLE DATE: June 1't, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR ( %) (ASTM C -231) WATER ADDED (gal): SLUMP (in .) (ASTM C -143) Tennis Court, northwest comer CONCRETE CYL[NDER'COMPRESSIVE STRENGTH TESTS Standard 6 1" 12", 28.27 squarer inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CNS 266 7 06/18/98 76000 2688 3000/28 days CNS 267 28 07/09/98 96000 3395 CNS 268 28 07/09/98 99000 3501 CNS 269 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of Fracture: o Curing: Methods: ASTM C -39 A® B C D REMARKS: Technician: Scott Rogers FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore