Loading...
SC-Coppell MSN-LR 980220FUGRO- McCLELLAND (SOUTHWEST), INC. �GRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date: February 20, 1998 PROJECT Coppell Elementary School #10, Coppell, Texas Project No .: 0771 -2089 SAMPLE DATE: January 22, 1998 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C - 1064) TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K.A Sparks 547153 CONCRETE SUPPLIER: Pioneer 43 PLANTITRUCK: 60 MIX ID NUMBER: 9337 11:40 a.m AIR ( %) (ASTM C -231) : CYLINDER 12:25 a.m WATER ADDED (gal): 0 Partly cloudy SLUMP (in.) (ASTM C -143) : 5 Compressor pad at northwest corner of building TESTED REMARKS: Technician: Skip Martin/ Roosevelt Webber FUGRO- McCLELLAND (SOUTHWEST), INC. Checked B / SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (Psi) CES 235 7 1/29/98 125000 4421 3000/28 days CES 236 28 2119/98 157000 5553 CES 237 28 2/19/98 160000 5659 CES 238 Hold Fracture mode is (A) unless otherwise noted Specifications: ! Making & ASTM C -31 ! Testing ASTM C -143, ! Types of Z Curing: Methods: ASTM C -39 Fracture: A® B® C D REMARKS: Technician: Skip Martin/ Roosevelt Webber FUGRO- McCLELLAND (SOUTHWEST), INC. Checked B / SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore