Loading...
SC-Coppell MSN-LR 971115. �� FUGRO- McCLELLAND (SOUTHWEST), INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISO Report Date: November 15, 1997 PROJECT Coppell Middle School North Sitework Coppell, Texas Project No .: 0771 -2094 SAMPLE DATE: October 16, 1997' CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Tiseo Paving 523340 CONCRETE SUPPLIER: Pioneer 65 PLANT /TRUCK: 27-0 76 MIX ID NUMBER: 9351 AGE AIR ( %) (ASTM C -231) : 5.2 10:05 am WATER ADDED (gal): 0 Clear SLUMP (in.) (ASTM C -143) : 5 Paving: Perimeter Road westbound lane, 100 feet east of Denton Tap CNS 93 7 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CNS 93 7 10/23/97 105000 3714 3000/28 days CNS 94 28 11/13/97 135000 1 4775 CNS 95 28 11/13/97 140000 4952 CNS 96 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of z Curing: Methods: ASTM C -39 Fracture: A® B C D REMARKS: Technician: Jason Brimingham FUGRO- McCLELLAND (SOUTHWEST), INC. Checked B . � ' SMH /rm Distribution: Coppell ISO - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore