Loading...
SC-Coppell MSN-LR 971028FUGRO-McCLELLAND (SOUTHWEST), INC. iiGRO ■ 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date: October 28, 1997 PROJECT: Coppell Middle School North, Coppell, Texas Project No.: 0771 -2091 SAMPLE DATE: September 25, 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks Contractors, Inc. 491141 CONCRETE SUPPLIER: Pioneer 78 PLANT /TRUCK: 74/754 90 MIX ID NUMBER: 9351 10:14 am AIR ( %) (ASTM C -231) LOAD 11:30 am WATER ADDED (gal): 0 Overcast SLUMP (in.) (ASTM c -143) : 5.0 Parking lot paving: 85 feet north of southwest corner, 10 feet east of west side 7 10/02/97 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMN 427 7 10/02/97 93000 3289 4000/28 days CMN 428 28 10/23/97 118000 4174 CMN 429 28 10/23/97 117000 4138 CMN 430 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, S Types of Fracture: Z 11 Curing: Methods: ASTM C -39 A® B® C D REMARKS: Technician: Bob Shea FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore 0 FUGRO- McCLELLAND (SOUTHWEST), INC. — � 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT Coppell ISD Report Date October 28, 1997 PROJECT Coppell Middle School North, Coppell, Texas Project No.: 0771 -2091 SAMPLE DATE: S eptember 25, 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks Contractors, Inc. 491136 CONCRETE SUPPLIER: Pioneer 78 PLANTITRUCK: 74/563 88 MIX ID NUMBER: 9351 9:50 am AIR ( % ) (ASTM C -231) LOAD (pounds) 10:50 am WATER ADDED (gal): 15 Overcast SLUMP (in .) (ASTM C -143) : 5.0 Parking lot paving, 75 feet north of southwest corner, 25 feet east of west side 7 10/02/97 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 127, 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER NUMBER AGE (days) DATE TESTED LOAD (pounds) STRENGTH (psi) STRENGTH (psi) CMN 423 7 10/02/97 120000 4244 4000/28 days CMN 424 28 10/23/97 145000 5129 CMN 425 28 10/23/97 143000 5058 CMN 426 Hold Specifications: Making & ASTM C -31 Curing: Fracture mode is (A) unless otherwise noted Testing ASTM C -143, Types of Methods: ASTM C -39 Fracture: A® B® C D REMARKS: Technician: Bob Shea FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: or-7--- SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore FUGRO- McCLELLAND (SOUTHWEST), IN 0 ■ 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date: October 28, 1997 PROJECT: Coppell Middle School North, Coppell, Texas Project No.: 0771 -2091 SAMPLE DATE: September 25, 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks Contractors, Inc. 491147 CONCRETE SUPPLIER: Pioneer 78 PLANT /TRUCK: 74/563 91 MIX ID NUMBER: 9351 11:23 am AIR ( %) (ASTM C -231) LOAD (pounds) 12:00 pm WATER ADDED (gal): 0 Overcast SLUMP (in.) (ASTM c -143) : 4.75 Parking lot paving: 125 feet north of southwest corner, 60 feet east of west side 10/02/97 108000 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6 "x'12", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER NUMBER AGE (days) DATE TESTED LOAD (pounds) STRENGTH (psi) STRENGTH (psi) CMN 431 7 10/02/97 108000 3820 4000/28 days CMN 432 28 10/23/97 127000 4492 CMN 433 28 10/23/97 130000 4598 CMN 434 Hold Specifications: Making & ASTM C -31 Curing: Fracture mode is (A) unless otherwise noted Testing ASTM C -143, Types of Methods: ASTM C -39 Fracture: A® B® C Z D REMARKS: Technician: Bob Shea FUGRO- McCLELLAND (SOUTHWEST), INC. Check By' SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore FUGRO-McCLELLAND (SOUTHWES INC. �GRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date: October 28, 1997 PROJECT Coppell Middle School North, Coppell, Texas Project No .: 0771 -2091 SAMPLE DATE: September 25 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks Contractors, Inc. 491153 CONCRETE SUPPLIER: Pioneer 78 PLANT /TRUCK: 74/751 91 MIX ID NUMBER: 9351 12:44 pm AIR ( % ) (ASTM C -231) : LOAD 1:10 pm WATER ADDED (gal): 0 Overcast SLUMP (in .) (ASTM C -143) : 5.25 Parking lot paving: 25 feet east of west side, 75 feet south of northwest corner CMN 435 7 CONCRETE CYLINDER'' COMPRESSIVE STRENGTH TESTS Standard 61 x 12", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMN 435 7 10/02197 105000 3714 4000/28 days CMN 436 28 10/23/97 118000 4174 CMN 437 28 10/23/97 121000 4280 CMN 438 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of Fracture: Curing: Methods: ASTM C -39 A® B® C D REMARKS: Technician: Bob Shea FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By. SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore FUGRO- McCLELLAND (SOUTHWEST), INC. 0 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT Coppell ISD Report Date: October 28, 1997 PROJECT Coppell Middle School North Sitework Coppell, Texas Project No.: 0771 -2094 SAMPLE DATE: September 29, 1997 - CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C -1064) TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Tiseo Paving 484591 CONCRETE SUPPLIER: Pioneer 82 PLANT /TRUCK: 27/121 88 MIX ID NUMBER: 9351 9:10 am AIR ( % ) (ASTM C -231) LOAD 9:35 am WATER ADDED (gal): 0 Clear SLUMP (in .) (ASTM C -143) : 41/2 Paving: Eastbound Natches Trace Drive, station 5 +00 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6 x 12 ", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CNS 1 7 10/06/97 84000 2971 3000/28 days CNS 2 28 10/27/97 110000 3891 CNS 3 28 10/27/97 113000 3995 CNS 4 1 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of Fracture: Z D Curing: Methods: ASTM C -39 A® B C REMARKS: Technician: Mark Strittmatter FUGRO- McCLELLAND (SOUTHWEST), INC. .s Checked By SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore FUGRO- McCLELLAND (SOUTHWEST), INC. M �� 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date: October 28, 1997 PROJECT Coppell Middle School North Sitework Coppell, Texas Project No.: 0771 -2094 SAMPLE DATE: September 29, 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Tiseo Paving 484613 CONCRETE SUPPLIER: Pioneer 85 PLANT /TRUCK: 27/Tiseo 88 MIX ID NUMBER: 9351 10:40 am AIR ( %) (ASTM C -231) LOAD 11:00 am WATER ADDED (gal): 0 Clear SLUMP (in.) (ASTM C -143) : 51/2 Paving: Eastbound Natches Trace Drive, station 8 +00 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CNS 5 7 10/06/97 80000 2829 3000/28 days CNS 6 28 10/27/97 105000 3714 CNS 7 28 10/27/97 110000 3891 CNS 8 Hold Fracture mode is (A) unless otherwise noted Specifications: '. Making & ASTM C -31 Testing ASTM C -143, Types of Fracture: Z s Curing: Methods: ASTM C -39 A® B C D REMARKS: Technician: Mark Strittmatter FUGRO- McCLELLAND (SOUTHWEST), INC. f Checked By: SMH /rm Distribution: Coppell ISD - Mickey Harper K A Sparks Contractors, Inc. K A Sparks Contractors, Inc. City of Coppell - Garreth Campbell - E. J. Williams (2) SHW Group - Joe Craddock - Jim Schooler SHW Group - Mike Elmore