SC-Coppell MSN-LR 971003M FUGRO- McCLELLAND (SOUTHWEST), INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 FIELD DENSITY REPORT CLIENT: Coppell ISD REPORT DATE: October 3, 1997 PROJECT: Coppell Middle School North Sitework, Coppell, Texas PROJECT NO.: 0771 -2094 DATE PERFORMED: September 19, 1997 MOISTURE /DENSITY RELATIONS Material Proctor Results Number Description Maximum Dry Density (pcf) Optimum Moisture ( %) 1 Tan, yellow, brown and gray shaley clay mix 105.5 20.2 TEST RESULTS TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF NO. NO. WEIGHT CONTENT PERCENT MAXIMUM DENSITY 187 1 West curb inlet approximately 175 feet 100.3 23.0 95.1 north and 100 feet east of southeast corner of building, southwest of P.A of middle school, final Remarks: All densities meet project specifications unless otherwise noted. Burl Cooper Fugro - McClelland Technician SMH /mv Distribution: Coppell ISD - Mickey Harper K A Sparks Contractors, Inc. - E. J. Williams (2) K A Sparks Contractors, Inc. - Jim Schooler FUGRO- McCLELLAND (SOUTHWEST), INC. Checked by: City of Coppell - Garreth Campbell SHW Group - Joe Craddock SHW Group - Mike Elmore FUGRO- McCLELLAND (SOUTHWEST), INC. ��� 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date October 3, 1997 PROJECT Coppell Middle School North, Coppell, Texas Project No.: 0771 -2091 SAMPLE DATE: September 24 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks 491055 CONCRETE SUPPLIER: Pioneer 75 PLANT /TRUCK: 74/491 88 MIX ID NUMBER: 9351 6:35 am AIR ( %) (ASTM C -231) LOAD 7:25 am WATER ADDED (gal): 15 Overcast SLUMP (in .) (ASTM C -143) : 5.0 Parking lot paving, 50 feet west of east, 50 feet north of southeast corner 1 10/01/97 119000 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMN 379 7 1 10/01/97 119000 4209 4000/28 days CMN 380 28 10/22/97 CMN 381 28 10/22/97 CMN 382 Hold Fracture mode is (A) unless otherwise noted Specifications: s Making & ASTM C -31 Testing ASTM C -143, Types of Fracture: Curing: Methods: ASTM C -39 A® B C D REMARKS: Technician: Bob Shea FUGRO- McCLELLAND (SOUTHWEST), INC. Checked B . SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore FUGRO- McCLELLAND (SOUTHWEST), INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date: October 3, 1997 PROJECT: Coppell Middle School North, Coppell, Texas Project No.: 0771 -2091 SAMPLE DATE: September 24 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks 491044 CONCRETE SUPPLIER: Pioneer 74 PLANT /TRUCK: 74/827 86 MIX ID NUMBER: 9351 5:28 am AIR ( %) (ASTM C -231) : LOAD 6:30 am WATER ADDED (gal): 5 Overcast SLUMP (in.) (ASTM C -143) : 5.0 Paving, parking lot, 25 feet north of southeast corner, 30 feet west of east side CMN 375 7 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMN 375 7 10/01/97 106000 3749 4000/28 days CMN 376 28 10/22/97 CMN 377 28 10/22/97 CMN 378 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of Curing: Methods: ASTM C -39 Fracture: A® B® C D REMARKS: Technician: Bob Shea FUGRO- McCLELLAND (SOUTHWEST), INC. Checked Bv. SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore FUGRO- McCLELLAND (SOUTH INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISO Report Date: October 3, 1997 PROJECT: Coppell Middle School North, Coppell, Texas Project No.: 0771 -2091 SAMPLE DATE: ''September 24, 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks Construction 491079 CONCRETE SUPPLIER: Pioneer 78 PLANT /TRUCK: 74 86 MIX ID NUMBER: 9351 8:55 am AIR ( %) (ASTM C -231) : LOAD 10:15 am WATER ADDED (gal): 25 Overcast SLUMP (in.) (ASTM C -143) : 5.25 Parking lot paving, 50 feet west of east side, 45 feet south of northeast corner 7 10/01/97 CONCRETE CYLINDER, COMPRESSIVE STRENGTH TESTS Standard '6" x'12"; 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMN 395 7 10/01/97 102000 3608 4000/28 days CMN 396 28 10/22/97 CMN 397 28 10/22/97 CMN 398 Hold Fracture mode is (A) unless otherwise noted Specifications: ' Making & ASTM C -31 Testing ASTM C -143, Types of € Curing: 9 Methods: ASTM C -39 Fracture: A® B® C D REMARKS: Technician: Bob Shea FUGRO- McCLELLAND (SOUTHWEST), INC. Checked B SMH /rm Distribution: Coppell ISO - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore -fu6R0 FUGRO-McCLELLAND (SOUTHWEST), INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date: October 3, 1997 PROJECT: Coppell Middle School North, Coppell, Texas Project No.: 0771 -2091 SAMPLE DATE: September 24:1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks 491068 CONCRETE SUPPLIER: Pioneer 77 PLANT /TRUCK: 74/567 88 MIX ID NUMBER: 9351 8:05 am AIR ( %) (ASTM C -231) LOAD 8:55 am WATER ADDED (gal): 0 Overcast SLUMP (in.) (ASTM C -143) : 6.0 Parking lot paving, 50 feet west of east side, 200 feet north of southeast corner CMN 387 7 CONCRETE CYLINDER COMPRESSIVE'' STRENGTH TESTS Standard 6" x 12 11 , 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMN 387 7 10/01/97 95000 3360 4000/28 days CMN 388 28 10/22/97 CMN 389 28 10/22/97 CMN 390 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of Curing: Methods: ASTM C -39 Fracture: A® B® C D REMARKS: Technician: Bob Shea FUGRO- McCLELLAND (SOUTHWEST), INC. Checked SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore FUGRO- McCLELLAND (S OUTHWEST), INC. . �.� 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date October 3, 1997 PROJECT Coppell Middle School North, Coppell, Texas Project No.: 0771 -2091 SAMPLE DATE: September 24,1997 CONTRACTOR: K. A. Sparks TICKET NO.: 491074 CONCRETE SUPPLIER: Pioneer AMBIENT TEMP. (°F): 77 PLANT /TRUCK: 74/661 CONCRETE TEMP. ( °F) (ASTM C- 1064) 88 MIX ID NUMBER: 9351 TIME BATCHED: 8:20 AIR ( % ) (ASTM C -231) : (psi) TIME SAMPLED: 9:40 WATER ADDED (gal): 7 WEATHER CONDITION: Overcast SLUMP (in .) (ASTM C -143) 28 LOCATION OF PLACEMENT: Parking lot paving, 10 feet west of east side, 65 feet south of northeast corner 28 10/22/97 CONCRETE CYLINDER''COMPRESSIVE STRENGTH TESTS Standard 6" x 12" 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMN 391 7 10/01/97 93000 3289 4000/28 days CMN 392 28 10/22/97 CMN 393 28 10/22/97 CMN 394 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of 0 a Curing: Methods: ASTM C -39 ? Fracture: A® B C D REMARKS: Technician: Bob Shea FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore FUGRO- McCLELLAND (SOUTHWEST), INC. — � 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD Report Date October 3, 1997 PROJECT Coppell Middle School North, Coppell, Texas Project No.: 0771 -2091 SAMPLE DATE: September 24 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks 491063 CONCRETE SUPPLIER: Pioneer 75 PLANT /TRUCK: 74/562 88 MIX ID NUMBER: 9351 7:34 am AIR ( %) (ASTM C -231) : LOAD 8:25 am WATER ADDED (gal): 15 Overcast SLUMP (in .) (ASTM C -143) : 4.75 Parking lot paving, 20 feet west of east side, 125 feet north of southeast corner 7 10/01/97 CONCRETE;' CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12' 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMN 383 7 10/01/97 105000 3714 4000/28 days CMN 384 28 10/22/97 CMN 385 28 10/22/97 CMN 386 Hold Fracture mode is (A) unless otherwise noted Specifications: i Making & ASTM C -31 Testing ASTM C -143, Types of i Fracture: Z 0 i Curing: Methods: ASTM C -39 A® B® C D REMARKS: Technician: Bob Shea FUGRO-MCCLELLAND (SOUTHWEST), INC. Checked By —� SMH /rm Distribution: Coppell ISD - Mickey Harper City of Coppell - Garreth Campbell K A Sparks Contractors, Inc. - E. J. Williams (2) SHW Group - Joe Craddock K A Sparks Contractors, Inc. - Jim Schooler SHW Group - Mike Elmore