Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Coppell Greens 1-LR 980828
FUGRO SOUTH, INC. '1~~ ~~ ~~~ 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Argus Development of Texas Inc, c/o Eastern Dev. Report Date: August 28, 1998 PROJECT: Coppell Greens, Phase I, Coppell, Texas Project NO.: 0771-2275 SAMPLE DATE: July 27, 1998 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTh1 C-1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Site Concrete CONCRETE SUPPLIER: On Site 88 PLANT/TRUCK: 86 MIX ID NUMBER: 9:30 AIR (%) (ASTM C-231) 10:00 WATER ADDED (gal): Clear SLUMP (in.) (ASTM c-143) : 5.0 Sidewalk, west side of Fallkirk and Applecrass Court CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE REQUIRED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) . CGS 105 7 8-3-98 113000 3997 3600/28 days CGS 106 28 8-24-98 130000 4598 CGS 107 28 8-24-98 131000 4633 CGS 108 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Curin : Testing ASTM C-143, Methods: ASTM C 39 Types of F t ® ~ g - rac ure: A g C D REMARKS: Technician: Greg Forsythe FUGRO SOUTH, INC. Checked By: ~ - SMH/kk Distribution: Eastern Development -Preston Skaggs Metro-Plex Excavating -Paul Bosco City of Coppell -Larry Davis