Coppell Greens 1-LR 980506FUGRO SOUTH, INC.
FIELD DENSITY REPORT
~GRO
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484-8301; Fax (972) 620-7328
CLIENT: Argus Development of Texas Inc, c/o Eastern Dev. REPORT DATE: May 6, 1998
PR0.IE CT: Coppell Greens, Phase I, Coppell, Texas PROJECT NO .: 0771-2275
Page 1
DATE PERFORMED: April 22, 'l998.
MOISTURE/DENSITY RELATIONS
Material Proctor Results
Number Description Maximum Dry Density (pci] Optimu m Moisture (%)
1 Dark brown and yellowish brown silty clay with 93.3 26.8
organics
2 Dark gray shaley clay 96.4 21.6
TEST RESULTS
TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF
NO. NO. WEIGHT CON TENT PERCENT MA XIMUM DENSITY
455 1 21 inch RCP, Line F, station 1+50, 3 feet 90.9 25.7 97.4
below grade
456 1 21 inch RCP, Line F, station 2+00, 2 feet 88.9 27.9 95.3
below grade
457 1 21 inch RCP, Line F, station 3+00, 3 feet 88.3 29.2 95.0
below grade
458 1 21 inch RCP, Line F, station 3+50, 1 foot 90.8 26.2 97.3
below grade
459 1 21 inch RCP, Lateral 2+95, station 0+50, 89.3 27.5 95.7
2 feet below grade
460 1 21 inch RCP, Lateral 2+95, station 0+60, 90.7 28.1 97.2
1 foot below grade
461 2 21 inch RCP, Line H, station 0+50, 3 feet 95.7 23.7 99.3
below grade
462 2 21 inch RCP, Line H, station 1+00, 4 feet 93.1 25.0 96.6
below grade
463 2 21 inch RCP, Line H, station 1+10, 3 feet 92.9 24.8 96.4
below grade
464 2 21 inch RCP, Line H, station 1+20, 2 feet 93.4 23.7 96.9
below grade
465 2 21 inch RCP, Line H, station 1+30, 1 foot 93.3 24.3 96.8
below grade
466 2 18 inch RCP, Line H, station 2+50, 4 feet 94.7 24.4 98.2
below grade
467 2 18 inch RCP, Line H, station 2+60, 3 feet 96.4 22.8 100.0
below grade
FUGRO SOUTH, INC.
_' ''~
~~
~~~
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484-8301; Fax (972) 620-7328
FIELD DENSITY REPORT
CLIENT: Argus Development of Texas Inc, c/o Eastern Dev. REPORT DATE: May 6, 1998
PROJECT: Coppell Greens, Phase I, Coppell, Texas PROJECT NO.: 0771-2275
Page 2
DATE PERFORMED:. April 22, 1998
TEST RESULTS
TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF
NO. NO. WEIGHT CONTENT PERCENT MAXIMUM DENSITY
468 2 18 inch RCP, Line H, station 2+70, 2 feet 92.5 25.1 96.0
below grade
469 2 18 inch RCP, Line H, station 2+80, 1 foot 91.3 24.8 95.0
below grade
Remarks: All densities meet project specifications unless otherwise noted.
Burl Cooper
Fugro South Technician
FUGRO SOUTH, INC.
Checked by: ~~ \~
SMHlmv
Distribution: Eastem Development Inc. -Preston Skaggs
Metro-Plex Excavating -Paul Bosco
City of Coppell -Larry Davis