Loading...
Coppell Greens 1-LR 980506FUGRO SOUTH, INC. FIELD DENSITY REPORT ~GRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 CLIENT: Argus Development of Texas Inc, c/o Eastern Dev. REPORT DATE: May 6, 1998 PR0.IE CT: Coppell Greens, Phase I, Coppell, Texas PROJECT NO .: 0771-2275 Page 1 DATE PERFORMED: April 22, 'l998. MOISTURE/DENSITY RELATIONS Material Proctor Results Number Description Maximum Dry Density (pci] Optimu m Moisture (%) 1 Dark brown and yellowish brown silty clay with 93.3 26.8 organics 2 Dark gray shaley clay 96.4 21.6 TEST RESULTS TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF NO. NO. WEIGHT CON TENT PERCENT MA XIMUM DENSITY 455 1 21 inch RCP, Line F, station 1+50, 3 feet 90.9 25.7 97.4 below grade 456 1 21 inch RCP, Line F, station 2+00, 2 feet 88.9 27.9 95.3 below grade 457 1 21 inch RCP, Line F, station 3+00, 3 feet 88.3 29.2 95.0 below grade 458 1 21 inch RCP, Line F, station 3+50, 1 foot 90.8 26.2 97.3 below grade 459 1 21 inch RCP, Lateral 2+95, station 0+50, 89.3 27.5 95.7 2 feet below grade 460 1 21 inch RCP, Lateral 2+95, station 0+60, 90.7 28.1 97.2 1 foot below grade 461 2 21 inch RCP, Line H, station 0+50, 3 feet 95.7 23.7 99.3 below grade 462 2 21 inch RCP, Line H, station 1+00, 4 feet 93.1 25.0 96.6 below grade 463 2 21 inch RCP, Line H, station 1+10, 3 feet 92.9 24.8 96.4 below grade 464 2 21 inch RCP, Line H, station 1+20, 2 feet 93.4 23.7 96.9 below grade 465 2 21 inch RCP, Line H, station 1+30, 1 foot 93.3 24.3 96.8 below grade 466 2 18 inch RCP, Line H, station 2+50, 4 feet 94.7 24.4 98.2 below grade 467 2 18 inch RCP, Line H, station 2+60, 3 feet 96.4 22.8 100.0 below grade FUGRO SOUTH, INC. _' ''~ ~~ ~~~ 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 FIELD DENSITY REPORT CLIENT: Argus Development of Texas Inc, c/o Eastern Dev. REPORT DATE: May 6, 1998 PROJECT: Coppell Greens, Phase I, Coppell, Texas PROJECT NO.: 0771-2275 Page 2 DATE PERFORMED:. April 22, 1998 TEST RESULTS TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF NO. NO. WEIGHT CONTENT PERCENT MAXIMUM DENSITY 468 2 18 inch RCP, Line H, station 2+70, 2 feet 92.5 25.1 96.0 below grade 469 2 18 inch RCP, Line H, station 2+80, 1 foot 91.3 24.8 95.0 below grade Remarks: All densities meet project specifications unless otherwise noted. Burl Cooper Fugro South Technician FUGRO SOUTH, INC. Checked by: ~~ \~ SMHlmv Distribution: Eastem Development Inc. -Preston Skaggs Metro-Plex Excavating -Paul Bosco City of Coppell -Larry Davis