Loading...
Service Star-LR061227 FIELD DENSITY TESTING Report Number: 94061329.0057 Service Date: December 19, 2006 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: Project: December 27, 2006 Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX 94061329 Project No.: Description and Classification Dark brown clay Lab Test Data Optimum Max. Lab Water Dry Unit Content Weight (%) (pct) 20.6 98.6 Proiect Requirements Material Information Material Laboratory No. Test Method 1 613290002 ASTM D 698 Field Test Data Test No. Water Content (%) -1/+3 Minimum Dry Unit Weight (% compaction) 95 Test Location Lift! Elev. Probe Mat. Depth No. (inches) Water Dry Unit Content Weight (%) (pet) Dry Unit Weight (% compaction) Pavement Subgrade, N of Firestone Bldg. 126 10' N & 30' E of NE cor. of Bldg. Final 1 6 20.1 97.1 98 127 20' N & 60' E of NE cor. of Bldg. Final 1 6 21.5 95.3 97 128 10' N & 110' E of NE cor. of Bldg. Final 1 6 20.3 96.8 98 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method: ASTM D-2922, ASTM D-3017 Terracon Rep: Christopher D. Harbour Field Results Reported To: Contractor Report Distribution: (1) ServiceStar Design Group LLC (1) City of Coppell TX (1) City of Coppell TX (1) lei Construction lnc (1) ICI Construction Inc (1) Pate Engineers (1) ServiceStar Design Group LLC (1) Ratliff Group LLC Reviewed by: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusivel or the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 07-PDRIR07"FUfure Key FIELD DENSITY TESTING Report Number: 94061329.0056 Service Date: December 14, 2006 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: Project: December 27,2006 Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX 94061329 Project No.: Description and Classification Dark brown clay Lab Test Data Optimum Max. Lab Water Dry Unit Content Weight (%) (pct) 20.6 98.6 Proiect Requirements Material Information Material Laboratory No. Test Method 1 613290002 ASTM D 698 Field Test Data Test No. Water Content (%) -1/+3 Minimum Dry Unit Weight (% compaction) 95 Test Location Lift! Elev. Probe Mat. Depth No. (inches) Water Dry Unit Content Weight (%) (pct) Dry Unit Weight (% compaction) Pavement Subgrade, Fire Lane E of Firestone Building 123 5' S & 10' E of NE cor. of Bldg. Final 6 19.9 97.2 99 124 30' S & 12' E of NE cor. of Bldg. Final 6 20.8 96.3 98 125 55'S&10'EofNEcor.ofBldg. Final 6 21.3 96.5 98 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method: ASTM D-2922, ASTM D-3017 Terracon Rep: Christopher D. Harbour Report Distribution: (1) ServiceStar Design Group LLC (1) City of Coppell TX (1) City of Coppell TX (1) ICI Construction Inc (1) lei Construction Inc (1) Pate Engineers (1) ServiceStar Design Group LLC (1) Ratliff Group LLC Reviewed by: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusi for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 07-ACS/R07-Future Key FIELD DENSITY TESTING Report Number: 94061329.0046 Service Date: December 12, 2006 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: Project: Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 December 27,2006 Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX 94061329 Project No.: Material Information Lab Test Data Optimum Max. Lab Water Dry Unit Content Weight ('Yo) (pcf) 20.6 98.6 Material Laboratory No. Test Method 1 613290002 ASTM D 698 Field Test Data Description and Classification Dark brown clay Probe Mat. Depth No. (inches) Test No. Lift! Elev. Final Final Final Final 1 1 1 1 6 6 6 6 20.0 22.1 21.6 23.3 Field Test Method: ASTM 0-2922, ASTM D-3017 Terracon Rep: Christopher D. Harbour Report Distribution: (1) ServiceSlar Design Group LLC (1) City of Coppell TX (1) City ofCoppell TX (1) ICI Construction Inc Proiect Requirements Water Content (%) -1/+3 97.7 95.1 95.9 93.5 Minimum Dry Unit Weight (% compaction) 95 Dry Unit Weight (% compaction) 99 96 97 95 (1) ICI Construction Inc (1) Pate Engineers (1) ServiceStar Design Group LLC (1) Ratliff Group LLC Water Dry Unit Content Weight (%) (pcf) Test Location Pavement, N & W Sides of Firestone Building 119 70' S & 25' W of NW cor. of Bldg. 120 10' S & 30' Wof NW cor. of Bldg. 121 25' N & 5' E of NW cor. of Bldg. 122 20' N & 65' E of NW cor. of Bldg. Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Reviewed by: The tests were performed in general accordance with applicable ASTM, MSHTO, or DOT test methods. This report is exclusively f the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 07-ACSJR07-Future Key Specification 3-5 4.5-7.5 CL NCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0054 Service Date: December 18, 2006 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 9:49 AM Plant: 01 Supplier: Nelson Bros. Ready Mix Truck No: 103 Ticket No: 172382 Mix 1.0. No.: PD36AEA Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pet: Result 4.75 2.8 77 75 145.6 * lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: December 27,2006 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: December 18, 2006 Time: 10:35 AM Sampled by: Eric G. Jernigan Weather Conditions: Partly cloudy, mild Accumulative Yards: 20/60 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: S Half of Fire Lane, (See attached sketch.) Placement Location: Pavement, Fire Lane & Center Drive/Approach to Bank Drive-Thru, (See attached sketch.) Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratory Test Data * = Field Test Results do not meet project specifications. Maximum Compressive Load Strength (Ibs) (psi) 95,590 3,380 Age at Set Specimen Diameter Area Date Test No. 10 (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 12/25/2006 7 1 2 01/15/2007 28 1 3 01/15/2007 28 1 4 02/12/2007 56 Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Field Results Reported To: Israel w/Westex TerraGon Rep: Eric G. Jernigan Report Distribution: (1) ServiceStar Design Group LLC (1) ICI Construclion Inc (1) City of Coppell TX (1) Pate Engineers Reviewed by: (1) Cily of Coppell TX (1) ServiceStar Design Group LLC L d J ~' P E (1) ICI Construction Inc (1) Ratliff Group LLC y~ on. x, . . Pnnclpal glneer The tests were performed in general accordance with applicable ASTM, MSHTO, or DOT test methods. This report is exclusively for e use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01.PDRJR01.FlJture Key W ? +-N r r;: ~ LJ \1 I 'i1z6~ff'"J l [3C/:>a. I ~-= I !~~~ I . r 0-0 Po Jld; !3L)tj . \ (]) - 9t1MflE fA taN l~7 - bp~~ rp6v(;D TC c,A'I ;;; r"~ YroN' ,;::- f,/Ob/329. ()()SiI /2-1$- ot,.. Terracon Report No.94061329.0054, Dated 12/18/2006 Multi-Facility Concept Specification 3-5 4.5-7.5 CuNCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0048 Service Date: December 13, 2006 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Materia/Information Specified Strength: 3500 psi @ 28 Days Batch Time: 7:38 AM Plant: 1 Supplier: Nelson Bros. Concrete Truck No: 220 Ticket No: 172168 Mix 1.0. No.: PD36AEA Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, OF: Plastic Unit Weight, pet: Result 6.00 6.1 61 58 N/A Laboratory Test Data lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: December 27,2006 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: December 13, 2006 Time: 8:15 AM Sampled by: Dustin R. Collins Weather Conditions: Clear Accumulative Yards: 10/120 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: Sample #1 on sketch Placement Location: Pavement, W of Firestone Bldg., from Send to 150' N of N end of Bldg., (See attached sketch.) Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Maximum Compressive Load Strength (Ibs) (psi) 107,800 3,810 Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 12/20/2006 7 1 2 01/10/2007 28 1 3 01/10/2007 28 1 4 02/07/2007 56 Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, MSHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 01-PDRlR01-Fulure Key Specification 3-5 4.5-7.5 CUNCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0048 Service Date: December 13, 2006 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 9:29 AM Plant: 1 Supplier: Nelson Bros. Concrete Truck No: 108 Ticket No: 172189 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pet: Result 5.50 5.5 63 61 N/A Laboratory Test Data Set No. 2 2 2 2 Specimen 10 1 2 3 4 Diameter Area (inches) (sq. inches) 6.00 28.27 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: December 27,2006 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: December 13, 2006 Time: 10:30 AM Sampled by: Dustin R. Collins Weather Conditions: clear Accumulative Yards: 110/150 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: Sample #2 on sketch Placement Location: Pavement, W of Firestone building, from S end to 150' N of N end of building, refer to attached sketch Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Date Tested 12/20/2006 01/10/2007 01/10/2007 02/07/2007 Age at Test (days) 7 28 28 56 Maximum Compressive Load Strength (Ibs) (psi) 123,670 4,370 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Dustin R. Collins Report Distribution: (1) ServiceStar Design Group LLC (1) lei Construclion Inc (1) City of Coppell TX (1) Pate Engineers Reviewed by: (1) City of Coppell TX (1) ServiceSlar Design Group LLC L d J C P E (1) ICI Construction Inc (1) Ratliff Group LLC yn on tti x, . . Princip E ineer The tests were performed in general accordance with applicable ASTM, MSHTO, or DOT test methods. This report is exclusively fo e use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 01-PDRiR01-FulureK..y ~ .~ ii.:. -,:,:~ :'::;:'", Jjr{~;otx-f: . J!;lJ~ -J'- ,: . ;':.1", '"= . -~-~:-'.--,-, :_' :'," .,~,....-::.-,' .'. ;. . ~ ,:i~ ~~---'" ;'-'-'-- .~_,c__ --- fZ~l- fjt!1ftCt mell+ /OCt.tt'Or\ (F~.(:;....r "'>>,"0;0 , - SI>. Jr\ pie. j OC o..t ; li h... ~ - ,c +: BIJ ~ ~X.'aj\ Terracon Report No. 94061329.0048 12/13/2006 Multi-Facility Concept