Service Star-LR061226 Specification 3-5 4.5-7.5 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0051 Service Date: December 15, 2006 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Materia/Information Specified Strength: 3500 psi @ 28 Days Batch Time: 7:27 AM Plant: 01 Supplier: Nelson Bros. Concrete Truck No: 219 Ticket No: 172311 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: - Gallons Water Added Onsite After Test: - Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pet: Result 5.00 2.0 67 57 148.3 * lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: December 26, 2006 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: December 15, 2006 Time: 8:20 AM Sampled by: Polikarp J. Labecki Weather Conditions: Cloudy Accumulative Yards: 30/130 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 30' S & 5' E of NW corner of pavement - Sample #1 on Sketch Placement Location: Pavement, Fire Lane & Parking Lot, E of Firestone Bldg., (See attached sketch.) Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Laboratory Test Data * = Field Test Results do not meet project specifications. Maximum Compressive Load Strength (Ibs) (psi) 118,660 4,200 Age at Set Specimen Diameter Area Date Test No. 10 (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 12/22/2006 7 1 2 01/12/2007 28 1 3 01/12/2007 28 1 4 02/09/2007 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, MSHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 01-PDRiR01-FulureK"y Specification 3-5 4.5-7.5 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0051 Service Date: December 15, 2006 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 9:18 AM Plant: 01 Supplier: Nelson Bros. Concrete Truck No: 223 Ticket No: 172326 Mix 1.0. No.: PD36AEA Water Added Onsite Before Test: -Gallons Water Added Onsite After Test: - Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pet: Result 5.00 5.5 67 59 142.6 Laboratory Test Data lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: December 26, 2006 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: December 15, 2006 Time: 10:10 AM Sampled by: Polikarp J. Labecki Weather Conditions: Cloudy Accumulative Yards: 110/130 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: Sample #2 on Sketch. Placement Location: Pavement, Fire Lane & Parking Lot, E of Firestone Bldg., (See attached sketch.) Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Maximum Compressive Load Strength (Ibs) (psi) 111,130 3,930 Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 2 1 6.00 28.27 12/22/2006 7 2 2 01/12/2007 28 2 3 01/12/2007 28 2 4 02/09/2007 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Lyndon J. C Principal E The tests were performed in general accordance with applicable ASTM, MSHTO, or DOT test methods. This report is exclusively for th use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Terracon Rep: Polikarp J. Labecki Report Distribution: (1) ServiceStar Design Group LLC (1) City of Coppell TX (1) City of Coppell TX (1) ICI Construction Inc (1) ICI Conslruction Inc (1) Pate Engineers (1) ServiceSlar Design Group LLC (1) Ralliff Group LLC Reviewed by: Page 2 of 2 01-PDR/R01.Fulure Key 11\ t-\tP~ iN '- ,.- - SIt~:t"l1orl ."#".2 pit y \ t.J (;,. J\- i< E A .#1 /~ /,/' Terracon Report No.94061329.0051, Dated 12/15/2006 Multi-Facility Concept