Loading...
Service Star-LR061208 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0010 Service Date: October 12, 2006 lrerracon o Gallons 10 Gallons 8901 Carpenter Frwy, Ste #1 00 Dallas, Texas 75247 (214) 630-1010 Report Date: December 08, 2006 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: October 12, 2006 Time: 2:00 PM Sampled by: Jeremy L. Robison Weather Conditions: Overcast Accumulative Yards: 4/4 Batch Size (cy): 4.00 Placement Method: Direct Discharge Sample Locations: Refer to placement location Placement Location: Storm Sewer Inlet Top Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 1 :25 PM Plant: 5 Supplier: Redi-Mix Concrete Truck No: 318 Mix 1.0. No.: 958 Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: 566429 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 3.00 2.8 81 68 148.6 Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Laboratory Test Data Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 104,810 3,710 28 143,360 5,070 28 141,490 5,000 Average (28 Days) 5,040 4 6.00 28.27 12/07/2006 56 165,750 5,860 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Set No. 1 1 1 Specimen 10 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Date Tested 10/19/2006 11/09/2006 11/09/2006 Terracon Rep: Jeremy L. Robison Report Distribution: (1) ServiceSlar Design Group LLC (1) City of Coppell TX (1) City of Coppell TX (1) ICI Construction Inc (1) ICI Construction Inc (1) Pate Engineers (1) ServiceSlar Design Group LLC (1) Ratliff Group LLC Reviewed by: ~ ,.~ Lyndon Ji ox, PE. Princip I ngineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for th se of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01-PDRIR01-FutUfe Key