Loading...
St Ann Catholic-LR061227CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061334.0006 Service Date: October 30, 2006 Irerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: December 27, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No.: 94061334 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 11:39 AM Plant: 3 Supplier: Lattimore Materials Co Truck No: 1053 Ticket No: 3222366 Mix I. D. No.: 1701 Water Added Onsite Before Test: 5 Gallons Water Added Onsite After Test: 0 Gallons Sample Information Date Cast: October 30, 2006 Time: 12:32 PM Sampled by: Ira S. Haynes Weather Conditions: Partly cloudy, windy Accumulative Yards: 80/160 Placement Method: Direct Discharge Sample Locations: Noted on sketch as Set #1 Placement Location: Paving, Parking Lot, refer to attached sketch Field Test Data Test Result Specification Test Metho Slump, inches: 5.00 3 -5 ASTM C143 Air Content, %: 3.7 3 -6 ASTM C231 Concrete Temperature, oF: 80 - ASTM C1064 Ambient Temperature,oF: 76 ASTM C1064 Plastic Unit Weight, pcf: N/A ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (s q. inches Tested (days (Ibs) (psi) 1 1 6.00 28.27 11/02/2006 3 82,660 2,920 1 2 6.00 28.27 11/06/2006 7 108,280 3,830 1 3 6.00 28.27 11/27/2006 28 141,830 5,020 1 4 6.00 28.27 11/27/2006 28 141,220 4,990 Average (28 Days) 5,010 1 5 6.00 28.27 12/25/2006 56 1 62,640 5,750 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 11 LC2r2/1Cl 1 —reKe, CONCRETE COMPRESSIVE STRENGTH TEST Irerracon b 94061334 0006 Report Num er. 8901 Carpenter Frwy, Ste #100 Service Date: October 30, 2006 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: December 27, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Pr oject No.: 94061334 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 12:40 PM Plant: 3 Supplier: Lattimore Materials Co Truck No: 1106 Ticket No: 3222380 Mix I.D. No.: 1701 Water Added Onsite Before Test: 5Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 4.0 Concrete Temperature, OF: 83 Ambient Temperature,OF: 78 Plastic Unit Weight, pcf: N/A Sample Information Date Cast: October 30, 2006 Time: 1:43 PM Sampled by: Ira S. Haynes Weather Conditions: Clear Accumulative Yards: - Placement Method: Direct Discharge Sample Locations: Noted on sketch as Set #2 Placement Location: Paving, Parking Lot, refer to attached sketch Specification 3 -5 3 -6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Ira S. Haynes Report Distribution: (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. (1) Page Soulherland Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 2 of 2 r ` "� � "`y * = Field Test Results do not meet project specifications. Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) ( sq. inches Tested (days (Ibs) (psi) 2 _ 1 6.00 28.27 11/02/2006 3 89,170 3,150 2 2 6.00 28.27 11/06/2006 7 106,200 3,760 2 3 6.00 28.27 11/27/2006 28 138,960 4,910 2 4 6.00 28.27 11/27/2006 28 134,880 4,770 Average (28 Days) 4,840 2 5 6.00 28.27 12/25/2006 56 1 5,410 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Ira S. Haynes Report Distribution: (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. (1) Page Soulherland Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 2 of 2 r ` "� � "`y F ----- = r n CO M f- _N9. EA L TERRACON REPORT NO � T�7 % - - - - -- — — — — — — ------- - - - - -- c) B' WATER LINE 0 1 U) cr 3 > EA T. 24' RCP Lr7 * tT