Loading...
St Ann Catholic-LR061226CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061334.0004 Service Date: October 23, 2006 Irerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: December 26, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Slump, inches: Project No.: 94061334 Material Information Sample Information Specified Strength: 3600 psi @ 28 Days Date Cast: October 23, 2006 Time: 9:22am 4.3 Sampled by: Ira S. Haynes Batch Time: 8:17am Plant: 3 Weather Conditions: Clear Supplier: Lattimore Accumulative Yards: 80 Truck No: 1050 Ticket No: 3222083 Placement Method: Direct Discharge Mix I.D. No.: 1701 Sample Locations: See attached sketch for Location #1 64 Placement Location: Pavement, Parking Lot Field Test Data Test Result Specification Test Metho Slump, inches: 5.00 3 -5 ASTM C143 Air Content, %: 4.3 3 -6 ASTM C231 Concrete Temperature, oF: 73 ASTM C1064 Ambient Temperature,oF: 64 ASTM C1064 Plastic Unit Weight, pcf: ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (s q. inches Tested (days (Ibs) (psi) 1 1 6.00 28.27 10/30/2006 7 95,190 3,370 1 2 6.00 28.27 11/20/2006 28 128,920 4,560 1 3 6.00 28.27 11/20/2006 28 128,420 4,540 Average (28 Days) 4,550 1 4 6.00 28.27 12/18/2 56 143,120 5,060 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1of2 p1ACSR01-F 1.K, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061334.0004 Service Date: October 23, 2006 Irerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: December 26, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX 1 Project No.: 94061334 Material Information Sample Information Specified Strength: 3600 psi @ 28 Days Date Cast: October 23, 2006 Time: 11:45am 28.27 Sampled by: Ira S. Haynes Batch Time: 11:06am Plant: 3 Weather Conditions: Clear Supplier: Lattimore Accumulative Yards: 140/156 Truck No: 5022 Ticket No: 3222096 Placement Method: Direct Discharge Mix I.D. No.: 1701 Sample Locations: See attached sketch for Location #2 Water Added Onsite Before Test: 15 Gallons Placement Location: Pavement, Parking Lot, N Parking Water Added Onsite After Test: 0 Gallons 144,700 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, OF Ambient Temperature,OF: Plastic Unit Weight, pcf: Result 5.25 4.3 83 77 Specification 3 -5 3 -6 Tact Mathnrl AJ I IVI L, 1415 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 * = Field Test Results do not meet project specifications. Laboratory Test Data Age at Set Specimen Diameter Area No. ID (inches) ( sq. inches 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Ira S. Haynes Report Distribution (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. (1) Page Southerland Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 "_"`s'�°'_`" °'a KIV Age at Maximum Compressive Date Test Load Strength Tested (days (lbs) (psi) 10/30/2006 7 103,510 3,660 11/20/2006 28 129,930 4,590 11/20/2006 28 128,920 4,560 Average (28 Days) 4,580 12/18/2006 56 144,700 5,120 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Ira S. Haynes Report Distribution (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. (1) Page Southerland Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 "_"`s'�°'_`" °'a KIV - - - - - - - - - - - - y ,1 I - - -- - -- ^ - - - - -- - - -- ° �� 17.0' I -_ 95.2 'PJ - z - a c a rn o P o 0 n l z —7— ._ � - - -- - -- _ - - - -- - - - -� ,o I t ,l I .219' rN r� cC Cl I+ y ®� -- — I s.a m - -- a m 77, ° I ! — (, c —_ — - W OHL I £ I I 3j RH - -- - - -- C c , 1 I cz o TF Tt o VI5151uT1 ES.MT. I — 1 j-�— VISIBILITY ESMT I I I, vas �zt5s Pc. z�s f I 23 -PT _88 ° 27'42 " W . S8 r 1 - — 2�5 _ _OS 40 "W 25 3_37' \ — - , WuL -