Loading...
Stoneleigh P1-LR 980710ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 0 1% (214) 620 -8911 TESTED FOR: FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT: STONELEIGH AT RIVERCHASE COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST DATE OF ISSUE: OUR REPORT NO.: JULY 10, 1998 97060 -262 FIELD DATA LOCATION OF CONCRETE PLACEMENT PAVING: 75 SOUTH & 40' WEST OF NW CORNER PLANT OF BUILDING 25 DATE PLACED 07/10/98 TIME 06:20 SLUMP (ASTM C -143) N/A AIR CONTENT (ASTM C -231 ❑ OR C -173 EU 4 AIR TEMPERATURE 83 CONCRETE TEMPERATURE 86 DATE RECEIVED 07/11/98 FIELD DATA SUBMITTED BY D.H. MIX DATA SUBMITTED BY REDI —MIX SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 R C 1231 ❑ & 40' WEST OF NW CORNER PLANT 1 DELIVER TICKET NO 17968 MIX PROPORTIONS (SSD) N/A CEMENT N/A WATER N/A FINE AGGREGATE N/A COARSE AGGREGATE N/A ADMIXTURE N/A COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C -39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 541 LAB 07/17/98 7 75,826 28.27 2,680 542 LAB 08/07/98 28 108,345 28.27 3,830 543 LAB 08/07/98 28 103,230 28.27 3,650 544 LAB HOLD H 28.27 Specifications 28 3,000 COM P U DATA -C G 01083 -34 REMARKS Cylinders made by ALPHA representative. ❑ Cylinders made by Architects or Contractor's representative. ylinders picked up by ALPHA laboratory. ❑ C linders delivered to ALPHA la tory. Compressions test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. Respectfully ub P T STETTNER ALPHA TESTING, INC. IF 2209 Wisconsin St. IX/1Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT: STONELEIGH AT RIVERCHASE COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST DATE OF ISSUE: OUR REPORT NO. JULY 10, 1998 97060 -261A FIELD DATA LOCATION OF CONCRETE PLACEMENT PAVING: 90 NORTH & 35' WEST OF SW CORNER PLANT OF BUILDING 24 DATE PLACED 07/10/99 TIME 04:40 SLUMP (ASTM C -143) 4f5 AIR CONTENT (ASTM C -231 11 OR C -173 N/A AIR TEMPERATURE 86 CONCRETE TEMPERATURE 90 DATE RECEIVED 07/11/98 FIELD DATA SUBMITTED BY D.H. MIX DATA SUBMITTED BY REDI —MIX / SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 R C -1231 ❑ & 35' WEST OF SW CORNER PLANT 1 DELIVER TICKET NO 17954 MIX PROPORTIONS (SSD) N/A CEMENT N/A WATER N/A FINE AGGREGATE N/A COARSE AGGREGATE N/A ADMIXTURE N/A COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C -39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 537 LAB 07/17/98 7 69,936 28.27 2,470 538 LAB 08/07/98 28 95,356 28.27 3,370 539 LAB 08/07/98 28 87,916 28.27 3,110 540 LAB HOLD H 28.27 Specifications 28 3,000 COM PU DATA- CGO1083 -34 REMARKS Cylinders made by ALPHA representative. ❑ Cylinders made by Architect's or Contractor's representative. ylinders picked up by ALPHA laboratory. ❑ Cylinders delivered to ALPHA labor ry. Compressions test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. a Q41 ectfully PAT STETTNER