Stoneleigh P1-LR 980604A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX 9721406 -8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR FIRST WORTHING COMPANY DATE 6/4/98 DALLAS, TEXAS PROJECT STONELEIGH AT RIVERCHASE OUR REPORT NO. 97060 -184 COPPELL, TEXAS TEST DATA: TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE �c MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT* 308 6/4198 FG-3.0 1 12.8 116.3 15.3 114 98 1 -A 309 6/4/98 FG -2.0 1 12.8 116.3 15.8 116 99 1 -A 310 6/4/98 FG -1.0 1 12.8 116.3 15.4 111 95 1 -A 311 6/4/98 FG 1 12.8 116.3 15.0 115 99 1 -A 312 6/4/98 FG 1 12.8 116.3 15.6 113 97 1 -A 313 8/4/98 FG 1 12.8 116.3 13.8 118 101 1 -A 314 6/4/98 FG 1 12.8 116.3 15.3 113 97 1 -A TEST LOCATION- 308 STATION 00 +40, 10'W OF CENTER LINE OF FAIRWAY DRIVE 309 STATION 00 +50, 5'W OF CENTER LINE OF FAIRWAY DRIVE 310 1 STATION #0+35, 10' W OF CENTER LINE OF FAIRWAY DRIVE 311 30'S AND 5'W OF SW CORNER OF BUILDING 14 312 30'S AND 10'E OF SE CORNER OF BUILDING 14 313 50' S AND 60' E OF SW CORNER OF BUILDING 13 314 1 55'S AND 40'W OF SE CORNER OF BUILDING 13 1. FILL # A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST Geotechrxcal Engineering g Cons/ fion Maferk& Tesfing g Environmental Engineering W Consuifing A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX. 97214016 -8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR FIRST WORTHING COMPANY DATE 6/4/98 DALLAS, TEXAS PROJECT TEST DATA: STONELEIGH AT RIVERCHASE OUR REPORT NO. 97060 -184A COPPELL, TEXAS TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 315 6/4/98 FG 1 12.8 116.3 15.7 113 97 1 -A TEST LOCATION: 315 145'S AND 45'W OF SE CORNER OF BUILDING _8 1 FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEMENTTREATED D. RETEST Geotechnical Engneeft g Consirucflon Materlawts Tesfing g Environmental Engirnemng w Consufhng A ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: FIRST WORTHING COMPANY DATE OF ISSUE: JUNE 4 1 1998 DALLAS, TEXAS PROJECT: STONELEIGH AT RIVERCHASE OUR REPORT NO.: 97060 -185 COPPELL, TEXAS COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C-39) LAB NO. TYPE CURING FIELD DATA AGE DAYS LOCATION OF CONCRETE PLACEMENT , APPROACH RIGHT OF WAY: 50' NORTH & 50' WEST OF 313 XV COMER OF BUILDING 8 7 DATE PLACED 06/04/98 PLANT N/A TIME 1100 30 DELIVER TICKET NO 102383 SLUMP (ASTM C -143) trJ MIX PROPORTIONS (SSD) N /A AIR CONTENT (ASTM C -231 ❑ OR C -173 'd7 5 : 2 CEMENT N/A AIR TEMPERATURE 7 5 WATER N/A CONCRETE TEMPERATURE 85 FINE AGGREGATE N /A DATE RECEIVED 06/05/98 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY J.T. ADMIXTURE N/A MIX DATA SUBMITTED BY REDI --MIX SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 R C -1231 ❑ COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C-39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 313 LAB 06/11/98 7 84,110 28.27 2,980 314 LAB 07/02/98 28 112,871 28.27 3,990 315 LAB 07/02/98 28 109,833 28.27 3,890 316 LAB HOLD H 28.27 Specifications 28 3,000 ( nh Ml —Tn nn -- — REMARKS Cylinders made by ALPHA representative. ❑ Cylinders made by Architect's or C tractor's representative. Cylinders picked up by ALPHA laboratory. ❑ Cylinders delivered to ALPHA labor tory. C�7 Compressions test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. R tfully A INC. PAT STETTNER A ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: FIRST WORTHING COMPANY DATE OF ISSUE: .TUNE 4, 1998 DALLAS, TEXAS PROJECT: STONELEIGH AT RIVERCHASE OUR REPORT NO.: 97060 -186 COPPELL, TEXAS COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C-39) LAB NO. TYPE CURING FIELD DATA AGE DAYS LOCATION OF CONCRETE PLACEMENT 30' FAST & 5' SOUTH OF NE CORNER OF 317 LAB BUILDING 8 7 79,522 DATE PLACED 06/04/98 PLANT N/A TIME 14:10 DELIVER TICKET NO 102397 SLUMP (ASTM C -143) 4 5 MIX PROPORTIONS (SSD) N/A AIR CONTENT (ASTM C -231 ❑ OR C -173 gA CEMENT N/A AIR TEMPERATURE 85 WATER N/A CONCRETE TEMPERATURE 85 FINE AGGREGATE N/A DATE RECEIVED 06/05/98 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY J.T. ADMIXTURE N/A MIX DATA SUBMITTED BY REDI —MIX / SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 R C -1231 ❑ COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C-39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 317 LAB 06/11/98 7 79,522 28.27 2,810 318 LAB 07/02/98 28 101,339 28.27 3,590 319 LAB 07/02/98 28 108,779 28.27 3,850 320 LAB HOLD H 28.27 Specifications 28 3,000 C O M P U DATA -C G 010 S 3 -34 REMARKS Cylinders made by ALPHA representative. ❑ Cylinders made by Architect's or Contractor's representative. Il inders picked up by ALPHA laboratory. ❑ Cylinders delivered to ALPHA l aboratory. 2"Compressions test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. El s ul m' d A , INC. PAT STETTNER ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT: STOIQELIE:IGH AT RIVERCHASE COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST DATE OF ISSUE: OUR REPORT NO. JUNE 4, 1998 97060 -187 COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C-39) LAB NO. TYPE CURING FIELD DATA AGE DAYS LOCATION OF CONCRETE PLACEMENT 40' EAST & 15' NORTH OF WE CORNER OF 321 LAB BUILDING 10 70,009 DATE PLACED 0 PLANT NIA TIME 16:30 DELIVER TICKET NO 16087 SLUMP (ASTM C -143) 4.7 MIX PROPORTIONS (SSD) N/A AIR CONTENT (ASTM C -231 ❑ OR C -173 8 CEMENT N/A AIR TEMPERATURE Y14. 90 WATER N/A CONCRETE TEMPERATURE 85 FINE AGGREGATE N/A DATE RECEIVED 06/05/98 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY J. T. ADMIXTURE N/A MIX DATA SUBMITTED BY REDI--MIX SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 OR C -1231 ❑ COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C-39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 321 LAB 06/11/98 7 70,009 28.27 2,480 322 LAB 07/02/98 28 103,757 28.27 3,670 323 LAB 07/02/98 28 100,998 28.27 3,570 324 i LAB HOLD H 28.27 Specifications 28 3,000 COM PU DATA- CGO1083 -34 REMARKS ylinders made by ALPHA representative. ❑ Cylinders made by Architect's or Contractor's representative. ylinders picked up by ALPHA laboratory. ❑ Cylinders delivered to ALPHA laboratory. C�Compressions test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. El &G, tted A INC. PAT STETTNER