Stoneleigh P1-LR 980522A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX: 9721406 -8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR FIRST WORTHING COMPANY DATE 5/22/98 DALLAS, TEXAS PROJECT TEST DATA: STONELEIGH AT RIVERCHASE OUR REPORT NO. 97060 -174A COPPELL, TEXAS TEST NO, DATE ELEV, DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXMAVM LAB DRYDENSrn PCF IN PLACE MOISTURE % IN PLACE DRYDENSTTY PCF PERCENT COMPACTION COMMENT• 291 5/22/98 FG 1 12.8 116.3 15.2 118 101 1 -A 292 5/22/98 FG 1 12.8 116.3 15.6 115 99 1 -A 293 5/22/98 FG 1 12.8 116.3 15.5 114 98 1-A LOCATION: PAVING OF NW CORNER OF BUILDING 9 292 135'W AND 15' S OF SW CORNER OF BUILDING 9 293 140'W AND 25'$ OF NW CORNER OF BULDING 11 1 FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBORADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D RETEST G 90technical Engineering g ConshLctlon MCtenc& Testing 0 Environmental Engineering X Consulting A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX 9721406 -8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR FIRST WORTHING COMPANY DATE 5/22/98 DALLAS, TEXAS PROJECT TEST DATA: STONELEIGH AT RIVERCHASE OUR REPORT NO. 97060 -174 COPPELL, TEXAS TEST NO. DATE ELEY. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXMMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COINPACTION COMMENT" 284 5/22198 FG 4 9.2 115.9 10.6 111 96 1 -A 285 5/22198 FG 1 12.8 116.3 15.0 118 101 1 -A 288 5122198 FG 1 12.8 116.3 14.4 112 96 1 -A 287 5/22/98 FG 1 12.8 116.3 15.0 118 101 1 -A 288 5/22198 FG 1 12.8 116.3 12.5 118 102 1 -A 289 5/22/98 FG 1 12.8 116.3 15.4 115 99 1 -A 290 5/22/98 FG 1 12.8 116.3 14.7 115 99 1 -A TEST LOCATION- PAVING 284 35'W AND 20'S OF SW CORNER OF BUILDING 8 285 50'S AND T E OF SE CORNER OF BUILDING 7 286 135'E AND 45'S OF SW CORNER OF BUILDING 8 287 75'S AND 10'W OF SW CORNER OF BUILDING 8 288 25'E AND 40'N OF SE CORNER OF BUILDING 6 289 130'E AND 10' S OF NE CORNER OF BUILDING 10 290 1 50'EAND 5' N OF SE CORNER OF BUILDING 10 t. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE S. PERCENT COMPACTION DOES NOT COMPLY WIT14 SPECIFICATIONS 3. LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST i Geotechnical Engineeft 0 Conshi.Icfion Materlds Testing g Environmental Engineering m Consutling ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT: STONELEIGH AT RIVERCHASE COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST DATE OF ISSUE: OUR REPORT NO MAY 22, 1998 97060 -176 FIELD DATA LOCATION OF CONCRETE PLACEMENT PAVING: 5' EAST & 50' SOUTH OF SE CORNER PLANT OF BUILDING 7 DATE PLACED 05/22/98 TIME 14:25 SLUMP (ASTM C -143) N/A AIR CONTENT (ASTM C -231 ❑ OR C -173 5 AIR TEMPERATURE 85 CONCRETE TEMPERATURE 89 DATE RECEIVED 05/23/98 FIELD DATA SUBMITTED BY A . W . MIX DATA SUBMITTED BY REDI —MIX SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ;10 -- R C -1231 ❑ & 50' SOUTH OF SE CORNER PLANT 1 DELIVER TICKET NO 15441 MIX PROPORTIONS (SSD) N/A CEMENT N/A WATER N/A FINE AGGREGATE N/A COARSE AGGREGATE N/A ADMIXTURE N/A COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C -39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 277 LAB 05/29/98 7 61,194 28.27 2,170 278 LAB 06/19/98 28 28.27 279 LAB 06/19/98 28 28.27 280 LAB HOLD H 28.27 Specifications 28 3,000 COMPU DATA- CGO1083 -34 REMARKS ylinders made by ALPHA representative. ❑ Cylinders made by Architect's or Contractor's representative. 4 ylinders picked up by ALPHA atory. ❑ Cylinders delivered to ALPHA laboratory. ❑ Compressions test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. ■❑ Respectfully Submitted ALPHA TESTING, INC. PAT STETTNER ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT STONELEIGH AT RIVERCHASE COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST DATE OF ISSUE OUR REPORT NO. MAY 22, 1998 97060 -175 FIELD DATA LOCATION OF CONCRETE PLACEMENT PAVING: 10' SOUTH & 60' EAST OF NE CORNER PLANT OF BUILDING 7 DATE PLACED 0 5 5/22/98 TIME 12:10 SLUMP (ASTM C -143) N/A AIR CONTENT (ASTM C -231 ❑ OR C -173 N/A AIR TEMPERATURE VA 79 CONCRETE TEMPERATURE 82 DATE RECEIVED 05/23/98 FIELD DATA SUBMITTED BY A.W. MIX DATA SUBMITTED BY REDI —MIX SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 OR C -1231 ❑ & 60' EAST OF NE CORNER PLANT 1 DELIVER TICKET NO 15415 MIX PROPORTIONS (SSD) N/A CEMENT N/A WATER N/A FINE AGGREGATE N/A COARSE AGGREGATE N/A ADMIXTURE N/A COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C -39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 273 LAB 05/29/98 7 82,336 28.27 2,910 274 LAB 06/19/98 28 28.27 275 LAB 06/19/98 28 28.27 276 I LAB HOLD H 28.27 Specifications 48 3,000 REMARKS lindens made by ALPHA representative. ❑ Cylinders made by Architect's or Contractor's representative. ❑ linders picked up by ALPHA I a oratory. ❑ Cylinders delivered to ALPHA laboratory. ❑ Compressions test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. Respectfully Submitted ALPHA TESTING, INC. PAT STETTNER COMPU DATA- CG01083 -34