Loading...
Stoneleigh P1-LR 980427A ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT: STONELEIGH AT RIVERCHASE COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST DATE OF ISSUE: APRIL 13, 1998 (REVISED 4/27/98) OUR REPORT NO.: 97060-120 FIELD DATA PAVING: 40' EAST & 15' SOUTH OF NE CORNER OF LOCATION OF CONCRETE PLACEMENT B 2 COMPRESSION TEST RESULTS (NOWNAL CYLINDER SIZE 6" X 12 ") (ASTM C -39) LAB NO. 04/13/98 DATE TESTED 5 DATE PLACED 11:45 1 PLANT 5 2 7 2 4 5 2 7 TIME * DELIVER TICKET NO 88,319 SLUMP (ASTM G143) 3,120 MIX PROPORTIONS (SSD) N/A AIR CONTENT (ASTM C-231 ❑ OR C-1 73121 86 CEMENT N/A AIR TEMPERATURE 83 WATER • N/A CONCRETE TEMPERATURE FINE AGGREGATE N/A DATE RECEIVED 04/14/98 COARSE AGGREGATE H FIELD DATA SUBMITTED BY F. M. ADMIXTURE N/A MIX DATA SUBMITTED BY REDI• —MIX � SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 ®'OR C -1231 ❑ COMPRESSION TEST RESULTS (NOWNAL CYLINDER SIZE 6" X 12 ") (ASTM C -39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 137 LAB 04/20/98 7 88,319 28.27 3,120 138 LAB 05/11/98 28 28.27 139 LAB 05/11/98 28 28.27 140 LAB HOLD H 28.27 Specifications 28 3,000 * CONTRACTOR INFORMED OF LOW AIR CONTENT AND HIGH SLiJMP REMARKS LIYCylinders made by ALPHA representative. ❑ Cylinders made by Architect's 7,11n rector's representative. picked up by ALPHA laboratory. ❑ Cylinders delivered to ALPHA laboratory. ❑ Compression test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. 0 Respectfully Submitted ALPHA TESTING, INC. PAT STETTNER