Loading...
Stoneleigh P1-LR 980423A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972 )620 -8911 FIRST WORTHING COMPANY TESTED FOR DALLAS, TEXAS PROJECT STONELEIGH AT RIVERCHASE COPPELL, TEXAS TEST DATA: REPORT OF FIELD COMPACTION TESTS DATE 04/23/98 OUR REPORT NO. 97060 -133 TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' AND 2 1 N 271 BUILDING 14, FROM NW CORNER OF 270 04/23 FG 1 12.8 116.3 13.6 114 98 1 -A 271 04/23 FG 1 1 12.8 116.3 12.8 120 103 1 -A TEST LOCATION: PAVING 270 BUILDING 14 FROM SW CORNER OF BUILDING 30 1 W AND 2 1 N 271 BUILDING 14, FROM NW CORNER OF BUILDING 15' S AND 2' W 1. FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST ALPHA TESTING, INC. ALPHA TESTING, INC. A 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620 -8911 FIRST WORTHING COMPANY TESTED FOR DALLAS, TEXAS PROJECT STONELEIGH AT RIVERCHASE COPPELL, TEXAS TEST DATA: REPORT OF FIELD COMPACTION TESTS DATE 04/23/98 OUR REPORT NO. 97060-132 TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE MAXIMUM LAB DRY DENSITY IN PLACE MOISTURE IN PLACE DRY DENSITY PERCENT COMPACTION COMMENT` 266 04/23 SG /FG 2 16.0 110.7 16.0 106 96 2 -A 267 04/23 SG /FG 2 16.0 110.7 16.0 108 98 2 -A 268 04/23 SG /FG 1 12.8 116.3 14.1 120 102 2 -A 269 04/23 SG /FG 1 12.8 116.3 13.6 114 98 2 -A 5, PARKING AREA TEST LOCATION: 266 20' S AND 50' E OF SW CORNER OF PAD 23, PARKING AREA 267 30' S AND 50' W OF SE CORNER OF PAD 23, PARKING AREA 268 20' S AND 30' E OF SE CORNER OF PAD 4, PARKING AREA 269 20' N AND 20' W OF NW CORNER OF PAD 5, PARKING AREA / 4 znl 1. FILL ' A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS I 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS s uII�Y bm/C. 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST H ING, CGO1083 -18