Stoneleigh P1-LR 980415ALPHA TESTING, INC.
2209 Wisconsin St.
Suite 100
Dallas, Texas 75229
(214) 620 -8911
TESTEDFOR: FIRST WORTHING COMPANY
DALLAS, TEXAS
PROJECT: STONELEIGH AT RIVERCHASE
COPPELL, TEXAS
REPORT OF CONCRETE
COMPRESSION TEST
DATE OF ISSUE:
OUR REPORT NO.:
APRIL 15, 1998
97060 -130
FIELD DATA
LOCATION OF CONCRETE PLACEMENT
1315 RIVERCHASE; EAST ENTRANCE
DATE PLACED
04/15/98
TIME
N/A
SLUMP (ASTM C -143)
N/A
AIR CONTENT (ASTM C -231 ❑ OR C
-173 ❑ )N /A
AIR TEMPERATURE
N/A
CONCRETE TEMPERATURE
N/A
DATE RECEIVED
04/16/98
FIELD DATA SUBMITTED BY
CONTRACTOR
MIX DATA SUBMITTED BY
N/A
SPECIMENS CAPPED IN ACCORDANCE
WITH ASTM C -617 ❑ OR C -1231 ❑
PLANT
N/A
DELIVER TICKET NO
331663
MIX PROPORTIONS (SSD)
N/A
CEMENT
N/A
WATER
N/A
FINE AGGREGATE
N/A
COARSE AGGREGATE
N/A
ADMIXTURE
N/A
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12 ")
(ASTM C -39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
161
LAB
04/23/98
8
82,199
28.27
2,910
162
LAB
05/13/98
28
132,526
28.27
4,690
163
LAB
05/13/98
28
122,851
28.27
4,350
164
LAB
HOLD
H
28.27
Specifications
REMARKS
Cylinders made by ALPHA
representative.
❑ Cylinders made by Architect's
or Contractor's representative.
ylinders picked up by ALPHA
laboratory.
❑ Cylinders delivered to ALPHA
laboratory.
ompression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
u
spectfully S Ti
P T STETTNER