Loading...
Stoneleigh P1-LR 980415ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTEDFOR: FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT: STONELEIGH AT RIVERCHASE COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST DATE OF ISSUE: OUR REPORT NO.: APRIL 15, 1998 97060 -130 FIELD DATA LOCATION OF CONCRETE PLACEMENT 1315 RIVERCHASE; EAST ENTRANCE DATE PLACED 04/15/98 TIME N/A SLUMP (ASTM C -143) N/A AIR CONTENT (ASTM C -231 ❑ OR C -173 ❑ )N /A AIR TEMPERATURE N/A CONCRETE TEMPERATURE N/A DATE RECEIVED 04/16/98 FIELD DATA SUBMITTED BY CONTRACTOR MIX DATA SUBMITTED BY N/A SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ❑ OR C -1231 ❑ PLANT N/A DELIVER TICKET NO 331663 MIX PROPORTIONS (SSD) N/A CEMENT N/A WATER N/A FINE AGGREGATE N/A COARSE AGGREGATE N/A ADMIXTURE N/A COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C -39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 161 LAB 04/23/98 8 82,199 28.27 2,910 162 LAB 05/13/98 28 132,526 28.27 4,690 163 LAB 05/13/98 28 122,851 28.27 4,350 164 LAB HOLD H 28.27 Specifications REMARKS Cylinders made by ALPHA representative. ❑ Cylinders made by Architect's or Contractor's representative. ylinders picked up by ALPHA laboratory. ❑ Cylinders delivered to ALPHA laboratory. ompression test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. u spectfully S Ti P T STETTNER