Loading...
Stoneleigh P1-LR 971118ALPHA TESTING, INC. A 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620 -8911 FIRST WORTHING COMPANY TESTED FOR DALLAS, TEXAS PROJECT STONELEIGHT AT RIVERCHASE COPPELL, TEXAS TEST DATA: REPORT OF FIELD COMPACTION TESTS DATE 11/18/97 OUR REPORT NO. 9'7060-17 TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 28 11/18 FG -5.0 1 20.0 1615.9 29 11/18 FG -4.0 1 20.0 100.9 22.9 100 100 1 —A 30 11/18 FG 1 20.0 100.9 24.0 100 99 1— TFST I n( ATION- 28 WEST BOUND, 60' N AND 2' E OF NW CORNER OF BUILDING 18 29 SEWER LINE STATION ##3 +75 30 SEWER LINE STATION #3 +80 1 FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS *Pyo 2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPFCIFICAT 1 )N` ^FME.NT TREATED i. RFTEST