Stoneleigh P1-LR 971117ALPHA TESTING, INC.
A 2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620 -8911
TESTED FOR FIRST WORTHING COMPANY
DALLAS, TEXAS
PROJECT STONELEIGH AT RIVERCHASE
COPPELL, TEXAS
TEST DATA:
REPORT OF FIELD
COMPACTION TESTS
DATE 11 /17/97
OUR REPORT NO. 97060
TEST
NO.
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
%
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT'
AT
STATION
1
+ 25
26
11-17
SG
1
20.0
100.9
23.5
99
98
1A
27
11 -17
FG
2
16.0
110.7
17.0
107
97
lA
TEST LOCATION:
26
SEWER
LINE
AT
STATION
1
+ 15
27
SEWER
LINE
AT
STATION
1
+ 25
1 FILL
2 NATURAL SUBGRADE
3 i_IME STABII IZED
4 CEMENT nFATF=r
Davin P. st
A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS —�
B. PERCENT C`7MPACTION DOES NOT COMPLY WITH SPECIFICATIONS -R� spectfully Submitt
G. PERCENT Ar;t MOISTUAF DOES NOT COMPLY WITH SPECIFICATIONS
RETEST ALPHA