Stoneleigh P1-LR 971117ALPHA TESTING, INC. A 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620 -8911 TESTED FOR FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT STONELEIGH AT RIVERCHASE COPPELL, TEXAS TEST DATA: REPORT OF FIELD COMPACTION TESTS DATE 11 /17/97 OUR REPORT NO. 97060 TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' AT STATION 1 + 25 26 11-17 SG 1 20.0 100.9 23.5 99 98 1A 27 11 -17 FG 2 16.0 110.7 17.0 107 97 lA TEST LOCATION: 26 SEWER LINE AT STATION 1 + 15 27 SEWER LINE AT STATION 1 + 25 1 FILL 2 NATURAL SUBGRADE 3 i_IME STABII IZED 4 CEMENT nFATF=r Davin P. st A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS —� B. PERCENT C`7MPACTION DOES NOT COMPLY WITH SPECIFICATIONS -R� spectfully Submitt G. PERCENT Ar;t MOISTUAF DOES NOT COMPLY WITH SPECIFICATIONS RETEST ALPHA