Loading...
ST9401-CS 980625 (2)rho der IM A 84M UM Future p.0. eo X 479 20 pARKWAY BL COppE, TX 73019 FAX NO. (972) 304 -3M ENGINEERING DEPARTMENT FAX COVER SHEET To: C-t Kll��u FROM: 6��tru�e - �� ° ��MP� -e-�� FIRM: R C�CO Iv PHONE NO.: FAX NO Z- 44�'�Z DATE: TRAMMED �'. TIME: NUMBER OF PAGES (INCLUDING COVER SHEET) z REMAR[C3' 0 5k 4 ( w '-) I c 6 M A.' % ME IF YOU DO NOT RECEIVE ALL OF THE mar cls, l y W1 PAGES* PLEASE CALL (972) 304 -3679. ,... 1341 West Mockingbird Lane •Dallas, Texas 75247 • 972.647.6700 • www.txi.com June 4, 1998 Rebcon, Inc. 1868 W. Northwest Highway Dallas, TX 75220 Attn: Mr. Robert Bibby r RE: Denton Tap Road City of Coppell 8272 8274 The attached concrete mix designs utilizing the appropriate ASTM C -33 or ASTM C -330 aggregate are proposed for use on the above referenced project for ready -mixed concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas Industries certifies that the above mix designs, when ordered by specified design identity, and delivered by TXI, will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of ACI Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Please contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix designs prior to their use. Failure to notify us prior to first placement shall constitute acceptance. To ensure that the proper mix designs are ordered, please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely, Texas Industries & Michael A. Caldarone, P.E. Manager - Q.A. / Q.C. Mix #: 8272 Description: 5.00SK ADMIX /AEA 1 11 CS Strength: 3000 psi Q 28 Days AS REQUIRED Maximum Coarse Aggregate: 1" - Maximum Water /Cement Ratio: 6.20 Cement /Cementitious Content: 5.00 Maximum Placement Slump: 4.00 Air Entraining Agent: ASTM Admixture: ASTM #4 CRUSHED STONE gal /sack or 0.549 lbs /lb sacks (per cubic yard) inches C -260 C -494 Type A or D MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 470 lbs. ASTM C 150 TYPE I CEMENT 1840 lbs. 1 - #4 CRUSHED STONE 1352 lbs. CONCRETE SAND 258 lbs. or 31.0 Gallons of Water 2.0 to 4.0 oz /cwt of - Specified Air Content- 3.0% - 6.0% Placement Slump: or - 1.00 inches Mix #: 8274 Description: 6.00SK ADMIX /AEA 1 11 CS Strength: 4000 psi Q 28 Days AS REQUIRED Maximum Coarse Aggregate: 1" - Maximum Water /Cement Ratio: 5.17 Cement /Cementitious Content: 6.00 Maximum Placement Slump: 4.00 Air Entraining Agent: ASTM Admixture: ASTM #4 CRUSHED STONE gal /sack or 0.457 lbs /lb sacks (per cubic yard) inches C -260 C -494 Type A or D MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 564 lbs. ASTM C 150 TYPE 1840 lbs. 1 - #4 CRUSHED 1273 lbs. CONCRETE SAND 258 lbs. or 31.0 Gallons 2.0 to 4.0 oz /cwt Specified Air Conte 3.0 Placement Slump: 3. I CEMENT STONE of Water TM C -494 - 1.00 inches