Loading...
Stoneleigh (Fairway)-LR 980603A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX: 9721406 -8023 TESTED FOR FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT STONELEIGH AT RIVERCHASE COPPELL, TEXAS TEST DATA: REPORT OF FIELD COMPACTION TESTS DATE 6/3/98 OUR REPORT NO. 97060 -1808 TEST NO. DATE ELEV. DEPTH SOfL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 301 6/3/98 SG +3.0 2 16 110.7 18.1 109 98 1 1 -A 302 6/3/98 SG +4.0 2 16 110.7 16.2 108 98 1 -A 303 6/3/98 SG +4.0 2 16 110.7 17.7 106 96 1 -A 304 6/3/96 SG +5.0 2 16 110.7 16.5 106 96 1 -A 305 6/3/98 SG +5.0 2 16 110.7 19.2 110 99 1 -A 306 6/3/98 SG +6.0 2 16 110.7 16.2 112 101 1 -A 307 6/3/98 SG +6.0 2 16 110.7 17.0 110 100 1 -A TEST LOCATION: FAIRWAY DRIVE DITCH BACKFILL 301 FAIRWAY DRIVE AT STATION #8 +75 302 FAIRWAY DRIVE AT STATION #8 +75 303 IFAIRWAY DRIVE AT STATION #8 +75 304 FAIRWAY DRIVE AT STATION #8 +75 305 FAIRWAY DRIVE AT STATION #8 +75 306 IFAIRWAY DRIVE AT STATION #8 +75 307 FAIRWAY DRIVE AT STATION #8 +75 t FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBORADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEMENTTREATFD D RETEST Geotechnical Engineering g Construction Materials Testing g Environmental Engineering a Consufhng A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620-8911 - 9721263 -4937 (Metro) FAX: 9721406 -8023 TESTED FOR FIRST WORTHING COMPANY DALLAS, TEXAS PROJECT STONELEIGH AT RIVERCHASE COPPELL, TEXAS TEST DATA: REPORT OF FIELD COMPACTION TESTS DATE 6/3/98 OUR REPORT NO. 97060 -180A TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT` 294 6/3/98 SG 2 16 110.7 17.1 110 99 1 1 -A 295 613/98 SG 2 16 110.7 19.1 107 97 i -A 296 6/3/98 SG +1.0 2 16 110.7 18.6 105 95 1 -A 297 6/3/98 SG +1.0 2 16 110.7 19.5 109 99 1 -A 298 6/3/98 SG +2.0 2 16 110.7 18.2 107 97 1 -A 299 6/3/98 SG +2.0 2 16 110.7 19.1 ill 100 i -A 300 6/3/98 SG +3.0 1 2 16 110.7 16.9 106 95 1 7 A TFGT i OC:ATIONl• FAIRWAY f)RIVF nIT(:H RACKFII_L_ 294 FAIRWAY DRIVE AT STATION #8 +75 295 FAIRWAY DRIVE AT STATION #8 +75 296 FAIRWAY DRIVE AT STATION #8 +75 297 FAIRWAY DRIVE AT STATION #8 +75 298 FAIRWAY DRIVE AT STATION #8 +75 299 FAIRWAY DRIVE AT STATION #8 +75 300 FAIRWAY DRIVE AT STATION #8 +75 I FILL rt A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS ;a NATURAL. SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3 LIME STABILIZED C PERCENT IN PLACE MOISTURE IXES NOT COMPLY WITH SPECIFICATIONS A CEMENTTREATED D. RETEST U S Itt2d ,IN Geotechnical Engineering g Construction Matena/s Testing g Environmental Engineering W Consulting