Stoneleigh (Fairway)-LR 980602A /I ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX: 9721406 -8023 TESTED FOR PROJECT TEST DATA: FIRST WORTHING COMPANY DALLAS, TEXAS STONELEIGH AT RIVERCHASE COPPELL, TEXAS REPORT OF FIELD COMPACTION TESTS DATE 6/2/98 OUR REPORT NO. 97060 -193A TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT 324 6/2/98 FG 3 15.9 112 15.5 111 99 1 -A 325 6/2198 FG 4 12.8 116.3 12.8 114 98 1 -A 326 6/2198 FG 4 12.8 116.3 11.9 111 95 1 -A 327 6/2/98 FG 4 12.8 116.3 11.8 111 95 1 -A 328 6/2/98 FG 4 12.8 116.3 12.5 116 100 1 -A 329 612/98 FG 4 12.8 116.3 11.9 116 99 1 -A 330 6/2/98 FG 4 12.8 116.3 12.5 116 100 1 -A TFST I nCATInN• PAVING 324 30'E AND 85'N FROM SE CORNER OF BUILDING 10 325 40'W AND 20'S FROM SW CORNER OF BUILDING 11 326 65'S AND 35'W FROM NW CORNER OF BUILDING 12 327 40'E AND 5'S FROM SW CORNER OF BUILDING 12 328 40'S AND 30'E FROM SE CORNER OF BUILDING 13 329 30'S AND 35'E FROM NE CORNER OF BUILDING 13 330 50'E AND 15'N FROM SE CORNER OF BUILDING 10 1 FILL A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS UI S 2d 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEMENT TREATED D RETEST STING,I Geotechnical Engineering g Conshuctlon Matertals Testing a Environmental Engineering a Consulting A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX: 9721406 -8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR FIRST WORTHING COMPANY DATE 6/2/98 DALLAS, TEXAS PROJECT TEST DATA: STONELEIGH AT RIVERCHASE OUR REPORT NO. 97060 -193B COPPELL, TEXAS TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 331 612/98 FG 4 12.8 116.3 12.5 112 96 1 -A TEST LOCATION: PAVING 331 150'N AND 40'W FROM SW CORNER OF BUILDING 11 1 FILL A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS :,/TING U Rted 3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS A CEMENTTREATFD D RETEST A H T f Geotechnical Engineering 11 Cons ruction Materials Testtng g EnVlronmental Engineering g Consufting