Valley R Plaza 2-LR 970623G1 EOTECHNICAL
7ENGINEERING GEE Consu ltants, Inc.
L E ] NVIRONMENTAL
10046 Monroe Drive • Dallas, Texas 75229 • (214) 352 -5433 • Fax (214) 352 -6972
REPORT OF CON CRETE MIX INSPECTION
Report Date: June 23, 1997 Date Concrete Placed: May 23, 1997 Standard 6 "x12"
Client: N.C. Inc. Area 28.27 Square Inches
Project: Valley Ranch Plaza Concrete Report No.: 25
Contractor: N.C. Inc. Project No.: 96 -0295
Concrete Supplier and Plant: Redi- Mix /l/ 1
Location of Placement: Paving
MATERIALS Source/ SSD Batch w ta. INSPECTION DATA
Description (Lbs /CuYd)
Mix Number:
731
Time Sample Batched:
09:40 am
Cement:
6 A
Time Sampled:
10:20 am
7
Sample Location:
Paving, 120' S. Of McDonalds curb
Fly Ash:
Truck /Ticket No:
610/14584
Coarse Aggregate:
06/20/97
Temperature:
4,410
Intermediate Aggregate:
VRP 103
Ambient Range:
72 °F
Fine Aggregate:
129,740
Concrete Range:
78 °F
VRP 104
Slump Range (inches):
4"
Admixtures:
Weather Conditions:
Partly Cloudy
1
AEA
Time Started:
09:15 am
2
Time Completed:
11:30 am
Added Water:
None
Sample Air Content (go):
4.5
Total Cubic Yards Placed:
10
Required Strength (Lbs. /sq.in.):
4,000 psi
Specimen
Number
Measured
Slump (in.)
Age
(Days)
Date
Tested
Total Load
(Lbs.)
Compressive Strength
(Lbs. /Sq.In.)
Remarks
VRP 101
7
05/30/97
104,900
3,710
VRP 102
28
06/20/97
124,780
4,410
VRP 103
4"
28
06/20/97
129,740
4,590
VRP 104
H
Hold
Test Methods Utilized
Fracture Regular
Cylinders Made By: AA
ASTM C- 31,C -39,C -143
(Unless Noted Otherwise)
Remarks and /or Distribution:
cc: Mr. Phil Holder - N.C., Inc., General Contractors
Mr. Ross Floyd - BMH, Inc.
Mr. John T. Evans - John T. Evans Company
Mr. Andy - AECC, Inc.
Mr. Garreth Campbell - City of Coppell (Parking Lot)
Mr. Lee Stone - City (,� Coppell (Building Pad)
GRE C onBIIlt ants, Inc. Reviewed byt
All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use of our name must receive
our prior written approval. Our letters and reports apply only to the sample tested and /or inspected and are not necessarily indicative of the quantities of apparently identical or similar products.