Loading...
Valley R Plaza 2-LR 970602EOTECHNICAL ENGINEERING GEE Consultants, Inc. L EJNVIRONMENTAL 10046 Monroe Drive • Dallas, Texas 75229 0 (214) 352 -5433 • Fax (214) 352 -6972 REPORT OF CONCRETE MIX INSPECTION Report Date: Client: Project: Contractor: Concrete Supplier and Plant: Locat of Placement: June 2, 1997 N.C. Inc. Valley Ranch Plaza N.C. Inc. Redi- Mix / #4 Paving Date Concrete Placed: May 6, 1997 Standard 6 "xl2" Area 28.27 Square Inches Concrete Report No.: 23 Project No.: 96 -0295 MATERIALS `mirce/ `SD Rath Wis. INSPECTION DATA VRP 93 Description (Lbs /CuYd) 103,940 Mix Number: 731 Time Sample Batched: 09:42 am Cement: 6 A Time Sampled: 10:40 am VRP 95 Sample Location: 20' W & 125' S. of N.E. corner of buildin) Fly Ash: Truck /Ticket No: 151/51800 Coarse Aggregate: Temperature: Hold Intermediate Aggregate: Ambient Range: 68 °F Fracture Regular Cylinders Made By: SP Concrete Range: 79 "F Fine Aggregate: Slump Range (inches): 614 Admixtures: Weather Conditions: Cloudy I AEA Time Started: 10:00 am 2 Time Completed: 12:05 pill Sample Air Content (40): 4 Added Water: None Total Cubic Yards Placed: 30 Required Strength (Lbs. /sq.in.): 4,000 psi Specimen Number Measured Slunnp(in.) Age (Days) Date Tested Total Load (l.bs.l Compressive Strength Mrs. /S(l .h1.) Remarks VRP 93 7 05/27/97 103,940 3,680 VRP 94 28 06/17/97 VRP 95 6 3 /4 " 28 06/17/97 VRP 96 H Hold Test Methods Utilized Fracture Regular Cylinders Made By: SP ASTM C- 31.-39.0 -143 C (Unless Noied Otherwise) Remarks and /or Distribution: cc: Mr. Phil Holder - N.C., Inc., General Contractors Mr. Ross Floyd - BMH, Inc. Mr. John T. Evans - John T. Evans Company Mr. Andy - AECC, Inc. GM Consultants, Inc. Reviewed by, All letters and reports are for the exclusive use of the client to whom they are addressed and shalt not be repn aced without rite full approval (it GFF ('onsuhrants. loc. I lie use of our lane must receive our prior written approval. Our letters and reports apply only to the sample rested and /or inspected and are tar necessarily indicative of the quantities of algnarendy identical or similar products. EOTECHNICAL C NGINEERING GEE Consultants, Inc. E I NVIRONMENTAL 10046 Monroe Drive • Dallas, Texas 75229 • (214) 352 -5433 • Fax (214) 352 -6972 REPORT OF CONCRETE MIX INSPECTION Report Date: Client: Project: Contractor: Concrete Supplier and Plant Location of Placement: MATERIALS June 2, 1997 N.C. Inc. Valley Ranch Plaza N.C. Inc. Redi- Mix /# 10 Paving Date Concrete Placed: May 2, 1997 Sllll rce: Stirs Balch wt'. Description (Lim/170 Standard 6 "x12" Area 28.27 Square Inches Concrete Report No.: 22 Project No.: 96 -0295 INSPECTION DATA Mix Number: 731 Time Sample Batched: Cement: 6 sk Time Sampled: Remarks VRP 85 Sample Location: Fly Ash: 05/09/97 97,880 Coarse Aggregate: I ntck /TAcket No: Intermediate Aggregate: 28 TenlpeYature: 129,340 4,570 Ambient Range: Fine Aggregate: 8" Concrete Range: Admixtures: 127,700 Slump Range (inches): I AEA Weather Conditions: 2 Hold 'Pirtle Started: Added Water: 0 gallons Time Completed: sample Air Content Fracture Regular Cylinders Made By: SP Total Cubic Yards Placed: (Unless Noted Otherwise) Required Strength (Lbs. /sq.in.): 100) alll 11:00 am 60' North & 5' West of Southwest Corner o Building, East of pavement 192/6121 84 °F 81 °F 8 " Clear 9:15 am 12:00 pin 2% 40 4,000 psi specimen Number Measured Slump (ill.) Age (DaysI Date I"tell Total Load (Lbs.) Compressive Strength (I,bsJSq.ln.l Remarks VRP 85 7 05/09/97 97,880 3,460 VRP 86 28 05/30/97 129,340 4,570 VRP 87 8" 28 05/30/97 127,700 4,520 VRP 88 H Hold Test Methods Utilized Fracture Regular Cylinders Made By: SP ASTM C- 31.0 -39.0 -143 (Unless Noted Otherwise) Remarks and /or Distribution: cc: Mr. Phil Holder - N.C., Inc., General Contractors Mr. Ross Floyd - BMH, Inc. Mr. John T. Evans - John T. Evans Company Mr. Andy - AECC, Inc. GM Consultants, Inc. Reviewed by, / r All letters and reports are for the exclusive use of the client to whom they are addressed antl shall txn be reprtaluced without the till approval of GFE Consultants. he. "I'he use of our acme must receive our prior written approval. Our letters and reports apply only to the sample tested and /or inspected mal are tan t+rcessarily hidicadve of tilt: quantities of apparently identical or similar products. EOTECHNICAL E I NGINEERING E I NVIRONMENTAL GEE Consultants, Inc. 10046 Monroe Drive Dallas, Texas 75229 • (214) 352 -5433 • Fax (214) 352 -6972 REPORT OF CONCRETE MIX INSPECTION Report Date: Client: Project: Contractor: Concrete Supplier and Plant Location of Placement: June 2, 1997 N.C. Inc. Valley Ranch Plaza N.C. Inc. Redi -Mix /# I Paving Date Concrete Placed: April 30, 1997 Standard 6 "x12" Area 28.27 Square Inches Concrete Report No.: 21 Project No.: 96 -0295 MATERIALS SO Description ssD nalch Wis INSPECTION DATA (Lbs /CuYd) Date ' rested Mix Number: 731 Time Sample Batched: 9:50 am Cement: 6 sk Time Sampled: 10:45 am 3,810 Sample Location: 20' South of second island from North Fly Ash: 05/28/97 'Tnlck /Ticket No: 163/13413 Coarse Aggregate: VRP 83 Tenlpervure: 28 Intermediate Aggregate: 126,760 Ambient Range: 90 "F Fine Aggregate: Concrete Range: 80eF Slump Range (inches): 5'/e" Admixtures: Cylinders Matte By: SP Weather Conditions: Clear 1 AEA Time Started: 9:45 am 2 Time Completed: 12:15 pin Added Water: lO gallons Sample Sample Air Content ( %): 3.5% Cubic Yards Placed: 40 Required Strength (Lbs. /sq.in.): 4,0(X) psi Specimen Number Measured slum m.) P (� Age (Days) Y Date ' rested Total Load (Lbs.) Compressive strength (Lhs. /sq.ln.) Remarks VRP 81 7 05/07/97 107,740 3,810 VRP 82 28 05/28/97 124,460 4,400 VRP 83 5 28 05/28/97 126,760 4,480 VRP 84 H Hold Test Methods Utilized ASTM C- 31,C -39,C -143 Fracture Regular (Unless Noted Orlwrwise) Cylinders Matte By: SP Remarks and /or Distribution: cc: Mr. Phil Holder - N.C., Inc., General Contractors Mr. Ross Floyd - BMH, Inc. Mr. John T. Evans - John T. Evans Company Mr. Andy - AECC, Inc. GUS Coneultanta, Inc. Reviewed by All letters and reports are for the exclusive use of tlx client to wbntn they are addressed and shall not Ix r prrxtured without Me full approval ul' GEE Cnnsuhants, Inc. The use of our nanx must receive our prior written approval. Our levers and reports aignly only to the sample tested and /or Inspected and arc -t necessarily itdicative of [lie quantities of apparently identical or similar products. G1 EOTECHNICAL E I NGINEERING E I NVIRONMENTAL GEE Consultants, Inc. 10046 Monroe Drive • Dallas, Texas 75229 0 (214) 352 -5433 • Fax (214) 352 -6972 REPORT OF CONCRETE MIX INSPECTION Report Date: June 2, 1997 Client: N.C. Inc. Project: Valley Ranch Plaza Contractor: N.C. Inc. Concrete Supplier and Plant: Redi- Mix /1#10 Location of Placement: Paving MATERIALS Date Concrete Placed: April 29, 1997 Source / SSI) Batch Wts. Description (Lbs /CuYd) Standard 6 "x12" Area 28.27 Square Inches Concrete Report No.: 20 Project No.: 96 -0295 INSPECTION DATA Mix Number: 731 Cement: 6 sk Fly Ash: 75 °F Coarse Aggregate: 8" Intermediate Aggregate: Clear Fine Aggregate: 9:45 am Admixtures: 12:45 pm 1 AEA 2 60 Added Water: 0 gallons Time Sample Batched: 10:31 am Time Sampled: 11:40 am Sample Location: Paving@ Northwestcomerof site, 150' Wes of McDonalds "Truck /Ticket No: 104/5933 Te nlpe)ratu re : Measured Slump (in.) Ambient Range: 84 °F Concrete Range: 75 °F Slump Range (inches): 8" Weather Conditions: Clear Time Started: 9:45 am Time Completed: 12:45 pm Sample Air Content (%): 3% Total Cubic Yards Placed: 60 Required Strength (Lbs. /sq.in.): 4,000 psi Specimen Number Measured Slump (in.) Age (Days) Dale Tcstcd Total Ltund (Lbs.) Cumpressive Strength (Lbs. /tiq.ln.) Remarks VRP 77 7 05/06/97 1 15,400 4,080 VRP 78 28 05/27/97 145,020 5,130 VRP 79 8" 28 05/27/97 143,560 5,080 VRP 80 H Hold Test Methods Utilized Fracture Regular Cylinders Made By: AJA ASTM C- 31,C -39,C -143 (Unless Noted Otherwise) Remarks and /or Distribution: cc: Mr. Phil Holder - N.C., Inc., General Contractors Mr. Ross Floyd - BMH, Inc. Mr. John T. Evans - John T. Evans Company Mr. Andy - AECC, Inc. GM Consultants, III Reviewed by, All letters and reports are for the exclusive use of the client to wham they are addressed and shall tvs Ix reI nl xluced without rile full approval of GEE Consultants, tic. 'rlle use of our name must receive our prior written approval. Our letters and reports apply only to the sample tested an dior inspected and are not mccssarily indicative of fire quantities of apparauly identical or similar products.