Loading...
Valley R Plaza 2-LR 970519EOTECHNICAL E I NGINEERING E I NVIRONMENTAL GEE Consultants, Inc. 10046 Monroe Drive • Dallas, Texas 75229 • (214) 352 -5433 • Fax (214) 352 -6972 REPORT OF CONCRETE MIX INSPECTION Cement: 6 sk Report Date: May 19, 1997 Date Concrete Placed: April 18, 1997 Standard 6 "xl2" Client: N.C. Inc. Fly Ash: Area 28.27 Square Inches Project: Valley Ranch Plaza Tempekture: Concrete Report No.: 18 Contractor: N.C. Inc. 86 °F Project No.: 96 -0295 Concrete Supplier and Plant: Redi- Mix / #5 76 °F Fine Aggregate: Location of Placement: Paving Admixtures: Weather Conditions: MATERIALS Source/ SSD Batch Wis. INSPECTION DATA 10:00 am 2 Description (Lbs/CuYd) 1:45 pm 4,670 Mix Number: 731 Time Sample Batched: 11:05 am Cement: 6 sk Time Sampled: 12:00 pin Remarks Sample Location: NW corner of site 200' W of McDonald's Fly Ash: Tnick /Ticket No: 181/50232 Coarse Aggregate: Tempekture: VRP 70 Intermediate Aggregate: Ambient Range: 86 °F 130,720 Concrete Range: 76 °F Fine Aggregate: Slump Range (incites): 5" Admixtures: Weather Conditions: Partly cloudy 1 AEA 'Tiine Started: 10:00 am 2 'Time Completed: 1:45 pm 4,670 Sample Air Content (f): 3% Added Water: 0 gallons g Total Cubic Yards Placed: 40 Required Strength (Lbs. /sq.in.): 4,000 psi Specimen Number Measured Slump (in.) Age (Days) Date Tested Total Load (Lbs.) Compressive Strength (Lbs. /Sq.In.) Remarks VRP 69 7 04/25/97 96,620 3,420 VRP 70 28 05/16/97 130,720 4,620 5 „ VRP 71 28 05/16/97 132,140 4,670 VRP 72 H Hold Test Methods Utilized Fracture Regular Cylinders Made By: AJA ASTM C- 31,C -39,C -143 (Unless Noted Otherwise) Remarks and/or Distribution: cc: Mr, Phil Holder - N.C., Inc., General Contractors Mr. Ross Floyd - BMH, Inc. Mr. John T. Evans - John T. Evans Company Mr. Andy - AECC, Inc. 1385 Consultants, Inc. Reviewed by, All letters and reports are for the exclusive use of the client to whom they are addressed and shall not he repr uced without the full approval of GEE Consultants, Inc. The use of our tame must receive our prior written approval. Our letters and reports apply only to the sample tested and /or inspected and are not necessarily indicative of the quantities of apparently identical or similar products. G1 EOrECHNICAL E I NGINEERING E I NVIRONMENTAL GEE Consultants, Inc. 10046 Monroe Drive • Dallas, Texas 75229 0 (214) 352 -5433 • Fax (214) 352 -6972 REPORT OF CONCRETE MIX INSPECTION Report Date: Client: Project: Contractor: Concrete Supplier and Plant Location of Placement: May 19, 1997 N.C. Inc. Valley Ranch Plaza N.C. Inc. Redi -Mix /f/ 1 Paving Date Concrete Placed: April 16, 1997 Standard 6 "x12" Area 28.27 Square Inches Concrete Report No.: 17 Project No.: 96 -0295 MATERIALS Source/ SSD Batch, Wis. INSPECTION DATA Description (Lbs /CuYd) Mix Number: Cement: Fly Ash: Coarse Aggregate: Intermediate Aggregate: Fine Aggregate: Admixtures: 1 2 Added Water: 731 Time Sample Batched: 12:02 pm 6 Sk Time Sampled: 1:05 pm Sample Location: 10' West & 27' East of center island (by road) Truck /Ticket No: 192/12800 Temperaidre: 7 Ambient Range: 68 °F Concrete Range: 66 °F Slump Range (Inches): 7" Weather Conditions: Clear Time Started: 10:30 am Time Completed: 1:45 pm Sample Air Content (3'0): 5 gallons 4% Total Cubic Yards Placed: 29 Required Strength (Lbs. /sq.in.): 4,000 psi Specimen Number Measured Slump (in.) Age (Days) Date Tested Total Load (Lbs.) Compressive Strength (Lbs. /Sq.In.) Remarks VRP 65 7 04/23/97 104,280 3,690 VRP 66 7 04/23/97 91,280 3,230 VRP 67 7" 28 05/14/97 121,380 4,290 VRP 68 28 05/14/97 135,700 4,800 Teat Methods Utilized ASTM (7-31,C-39,C-143 Fracture Regular (Unless Note) Otherwise) Cylinders Made By: DF Remarks and /or Distribution: cc: Mr. Phil Holder - N.C., Inc., General Contractors Mr. Ross Floyd - BMH, Inc. Mr. John T. Evans - John T. Evans Company Mr. Andy - AECC, Inc. OM Consultants, Inc. Reviewed by, _. --- 7k - -- All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use of our carne must receive our prior written approval. Our letters and reports apply only to the sample tested andlor inspected and are not necessarily indicative of the quantities of apparently identical or similar products.