Valley R Plaza 2-LR 970401EOTECHNICAL
E I NGINEERING
GEE Consultants, Inc.
L E I NVIRONMENTAL
10046 Monroe Drive • Dallas, Texas 75229 • (214) 352 -5433 • Fax (214) 352 -6972
REPORT OF IN -PLACE DENSITY AND MOISTURE OF SOIL
Density Report No. 16 (96 -295) Method:- ASTM D2922 D3017 D698 Page 1 of 1
Client: N.C. Inc.
Material Description
Maximum
Optimum
Dry
Moisture
Density
Content
Project: Valley Ranch Plaza
(Lbs /CuFt)
Percent
1. Yellowish Brown and Dark Gray Clay
105.5
17.2
Test Date: March 28, 1997
2. Dark Gray and Dark Brown Shalcy Clay
94.2
22.6
3. (S.F.) Reddish Brown Sandy Clay with sonic gravel
121.0
10.2
Report Date: April 1, 1997
Required Density ( %): Min. 95%
Required Moisture ( %): Opt ±3
Mat
Location /Elevation (and /or) Lift
In -Place
In -Place
Percent
No.
Dry Density
Moisture
Compaction
Test
(Lbs /CuFt)
Content ( %)
Probe
No.
Depth
1
Parking Lot; Northeast of Building
39
40' East and 5' North of Northeast corner
104.5
20.2
99.0
6 "
2
Parking Lot; Northeast of Building
38
5' East and 20' North of Northeast corner
97.6
22.7
103.6
6"
i +u tests meet project speclncauons
cc: Mr. Phil Holder - N.C., Inc., General Contractors
Mr. Ross Floyd - BMH, Inc. _ /
Mr. John T. Evans - John T. Evans Company t /
Andy - AECC, Inc. I
Our letters and reports are for the exclusive use of the client to whom they are addressed. The use of our name must receive our prior written approval. Our
letters and reports apply only to the sample tested and/or inspected, and are not necessarily indicative of the quantities of apparently identical or similar products.