Vista Properties-LR 961030A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
TESTED FOR:
PROJECT:
REPORT OF FIELD
COMPACTION TESTS
CENTEX HOMES (F /K /A VISTA PARTNE]i4iE 10/30/96
DALLAS, TEXAS
SANITARY SEWER & WATER OUR REPORT NO. 96562 -32
IMP. - VISTA RIDGE, AREA F
COPPELL, TEXAS
TEST
NO.
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
MOISTURE
DRY DENSITY B
PCF
MOISTURE
%
DRY DENSITY
PCF
COMPACTION
COMMENT*
10/30
FG -10.0
1
20.5
99.5
20.9
96
97
1 -A
26
FG -9.0
1
20.5
99.5
21.2
95
96
1 -A
27
10/30
FG -8.0
1
20.5
99.5
20.8
97
97
1 -A
28
10/30
FG -7.0
1
20.5
99.5
21.6
96
97
1 -A
29
10/30
G -6.0
1
20.5
99.5
21.0
97
97
1 -A
30
10/30
FG -5.0
1
20.5
99.5
21.7
95
96
1 -A
31
10/30
FG -4.0
1
20.5
99.5
21.3
96
96
1 -A
32
10/30
-- 1 ^l ATIAAI-
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS 4ALTPHA tfully Submitted,
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS