Loading...
Vista Properties-LR 961023A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF FIELD COMPACTION TESTS CENTEX HOMES (F /K /A VISTA PARTNERS) 10/23/96 TESTED FOR: DALLAS, TEXAS DATE: PROJECT: SANITARY SEWER & WATER OUR REPORT NO. 96562 - 30 IMP. - VISTA RIDGE, AREA F COPPELL, TEXAS TEST DATA TEST NO DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 209 10/23 FG -16.0 3 16.6 106,6 18.4 104 97 1 -A 210 10/23 FG -15.0 3 16.6 106.6 19.4 102 96 1 -A 211 10/23 FG -14.0 3 16.6 106.6 19.7 102 95 1 -A 212 10/23 FG -13.0 3 16.6 106.6 16.9 105 98 1 -A 213 10/23 FG -12.0 3 16.6 106.6 18.0 104 97 1 -A 214 10/23 FG -11.0 3 16.6 106.6 20.0 102 95 1 -A 215 10/23 FG -10.0 3 16.6 106.6 17.5 103 97 1 -A TEST LOCATION: 209 SANITARY SEWER LINE "E" AT STATION #2-1.75 210 SANITARY SEWER LINE "E" AT STATION #2 +75 211 SANITARY SEWER LINE "E" AT STATION #2 +75 212 SANITARY SEWER LINE "E" AT STATION #2 +85 213 SANITARY SEWER LINE "E" AT STATION #2 +85 214 SANITARY SEWER LINE "E" AT STATION #2 +85 215 SANITARY SEWER LINE "E" AT STATION #2 +90 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS especttully Submitted 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS AL C STIN � 4. CEMENT TREATED D. RETEST c� Cooioes -1a A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: PROJECT: TEST DATA REPORT OF FIELD COMPACTION TESTS CENTEX HOMES (F /K /A VISTA PARTNERS) 10/23/96 DALLAS, TEXAS DATE: SANITARY SEWER & WATER OUR REPORT NO. 96562 -30A IMP. — VISTA RIDGE, AREA F COPPELL, TEXAS TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE MAXIMUM LAB DRY DENSITY pCF IN PLACE MOISTURE / IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT" 216 10/23 FG-9.0 3 16.6 106.6 20.2 103 97 1 —A 217 10/23 FG -8.0 1 20.5 99.5 27.4 95 95 1 —C 218 10/23 FG -7.0 1 20.5 99.5 26.3 95 95 1 —C TEST LOCATION: 216 SANITARY SEWER LINE "E" AT STATION #2 +95 217 SANITARY SEWER LINE "E" AT STATION #2 +95 218 SANITARY SEWER LINE "E" AT STATION #2 +95 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Res tfully Submitted, 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS PHA TESTING, IN 4. CEMENT TREATED D. RETEST C00 OS3 8 < AL r _�