Vista Properties-LR 961017A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: PROJECT: TFST nATA REPORT OF FIELD COMPACTION TESTS CENTEX HOMES (F /K /A VISTA PARTNERS) DALLAS, TEXAS DATE: SANITARY SEWER & WATER OUR REPORT NO IMP. — VISTA RIDGE, AREA F COPPELL, TEXAS 10/17/96 96562 -28 TEST NO. DATE ELEV. DEPTH SOIL ID NUM BER OPTIMUM MOISTURE i MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE i IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT" 202 10/17 FG -6.0 1 20.5 99.5 23.4 95 96 1 -A 20 10/17 FG -5.0 1 20.5 99.5 20.6 97 97 1 -A 20 10/17 FG -4.0 1 20.5 99.5 21.4 96 97 1 -A 205 10/17 FG -3.0 1 20.5 99.5 22.8 97 97 1 -A 20E 10/17 FG -2.0 1 20.5 99.5 24.1 96 96 1 -A 20 10/17 FG -1,0 1 20.5 99.5 23.6 96 97 1 -A 20 10/17 FG 1 20.5 99.5 24.1 95 96 1 -A TCCT 1 Af`ATI(]N- 20 SANITARY SEWER LINE "E" AT STATION #1 +90 20 SANITARY SEWER LINE "E" AT STATION #1 +90 204 SANITARY SEWER LINE "E" AT STATION #1 +90 20 SANITARY SEWER LINE "E" AT STATION #2 +00 20 SANITARY SEWER LINE "E" AT STATION #2 +00 20 SANITARY SEWER LINE "E" AT STATION #2 +10 20E SANITARY SEWER LINE "E" AT STATION #2 +10 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED A. TEST RESULTS COMPLY WITH SPECIFICATIONS Respectfully Submitted, B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTINQQ; iNG D. RETEST Pat Stettne 1 CG01 063 -19