Vista Properties-LR 961010A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
REPORT OF FIELD
COMPACTION TESTS
CENTEX HOMES (F /K /A VISTA PARTNERS) 10/10/96
TESTED FOR: DALLAS, TEXAS DATE:
PROJECT: SANITARY SEWER & WATER OURREPORTNO. 96562 - 27
IMP. - VISTA RIDGE, AREA F
COPPELL, TEXAS
TEST DATA:
TEST I
NO.
DATE
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
%
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT`
196
10/10
FG-14.0
1
20.5
99.5
20.8
100
100
1 -A
197
10/10
FG-13.0
1
20.5
99.5
20.5
102
102
1 -A
198
10/10
FG-12.0
1
20.5
99.5
20.6
99
100
1 -A
199
10 /10
FG -11.
1
20.5
99.5
20.9
100
101
1 -A
200
10/10
FG-10.0
1
20.5
99.5
21.0
100
101
1 -A
201
10 /10
FG- 9.0
1
20.5
99.5
20.7
100
100
1 -A
TEST LOCATION:
196
UTILITY
LINES,
10"
SANITARY
SEWER
LINE
E
AT
STATION
#1 +50
197
UTILITY
LINES,
10"
SANITARY
SEWER
LINE
E
AT
STATION
#1 +48
198
UTILITY
LINES,
10"
SANITARY
SEWER
LINE
E
AT
STATION
#1 +46
199
UTILITY
LINES,
10"
SANITARY
SEWER
LINE
E
AT
STATION
01 +44
200
UTILITY
LINES,
10"
SANITARY
SEWER
LINE
E
AT
STATION
#1 +42
201
UTILITY
LINES,
10"
SANITARY
SEWER
LINE
E
AT
STATION
#1 +40
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
4. CEMENT TREATED D. RETEST
COOIOB3 -18
Res ally Submitted,
'ALPHA TESTING, I
Pat Step er