Vista Properties-LR 960927A ALPHA TESTING, INC. 2209 Wisconsin St. Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: CENTEX HOMES DATE OF ISSUE: SEPTEMBER 27, 1996 C/O DOWDEY, ANDERSON & ASSOC. DALLAS, TEXAS PROJECT: SANITARY SEWER & WATER IMPROVEA*Wq�EPORTNO 96562 -23 VISTA RIDGE, AREA F COPPELL /LEWISVILLE, TEXAS COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C -39) LAB NO. TYPE C FIELD DATA AGE OT TAL DAYS LOAD LOCATION OF CONCRETE PLACEMENT SOUTH PIER, SANITARY SEWER LINE "A" @ STATION 11+25 DATE PLACED 09/20/96 PLANT 41 TIME 2: 45 DELIVER TICKET NO 668242 SLUMP (ASTM C -143) 3.0 MIX PROPORTIONS (SSD) N/A AIR CONTENT (ASTM C -231 F] OR C -173 F N/A CEMENT N/A AIR TEMPERATURE 82 WATER N/A CONCRETE TEMPERATURE 83 FINE AGGREGATE N/A DATE RECEIVED 09/21/96 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY ZM ADMIXTURE N/A MIX DATA SUBMITTED BY TX I SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 !, OR C -1231 COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12 ") (ASTM C -39) LAB NO. TYPE C DATE TESTED AGE OT TAL DAYS LOAD AREA COMPRESSIVE STRENGTH, PSI 1 LAB 09/27/96 7 142,650 28.27 5,050 2 LAB 10/18/96 28 164,050 28.27 5,800 3 LAB 10/18/96 28 174,280 28.27 6,160 4 LAB HOLD H 28.27 I Specifications 2 8 � 000 COMPU DATA- CG01083 -34 REMARKS Minders made by ALPHA representative. ❑ Cylinders made by Architect's or Contractor's representative. Iylinders picked up by ALPHA laboratory. ❑ Cylinders delivered to ALPHA laboratory. G'Compressions test results comply with applicable specifications. J Compression test results do not comply with applicable specifications. Resp�Ectf Ily Submitte AL- bfA�ESTING, DAVID (PAT) STETTNER