Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Vista Properties-LR 960913
A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: CENTEX HOMES C/O DOWDEY, ANDERSON & ASSOC. DALLAS, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/13/96 PROJECT: OUR REPORT NO. SANITARY SEWER & WATER IMPROVEMENTS 96562 -19 VISTA RIDGE, AREA F COPPELL /LEWISVILLE, TEXAS TCCT nATA• TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER MOISTURE % DRY MAXIMUM DENSITY PCF MOISTURE % DRY DENSITY PCF COMPACTION COMMENT` 152 j 09/13 FG -13.0 1 20.5 99.5 21.6 3 +25 ---l= 153 1 09/13 FG -12.0 1 20.5 99.5 20.9 96 97 1 -A 154 09/13 FG -11.0 1 20.5 99.5 21.3 96 96 - 155 156 09/13 09/13 FG -10.0 FG -9.0 1 1 20.5 20.5 99.5 99.5 21.9 20.7 97 97 - 1 -A 157 09/13 FG -8.0 1 20.5 99.5 21.6 95 1 96 1 -A 158 09/13 FG -7.0 1 20.5 99.5 21.9 95 I- 152 10" SANITARY SEWER LINE "D" @ STATION 3 +50 153 10" SANITARY SEWER LINE "D" @ STATION 3 +25 10" SANITARY SEWER LINE "D" @ STATION 3 +00 154 155 10" SANITARY SEWER LINE "D" @ STATION 2 +75 156 10" SANITARY SEWER LINE "D" @ STATION 2 +50 157 10" SANITARY SEWER LINE "D" @ STATION 2 +25 158 10" 1. SANITARY SEWER LINE "D" @ STATION 2 +00 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS R ectfully Submitted 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTIN 4. CEMENT TREATED D. RETEST CGO1083 -18 David P� t e t e r A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: CENTEX HOMES C/O DOWDEY, ANDERSON & ASSOC. DALLAS, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 09/13/96 PROJECT: OUR REPORT NO. SANITARY SEWER & WATER IMPROVEMEN`T'S 96562 -19A VISTA RIDGE, AREA F COPPELL /LEWISVILLE, TEXAS A. TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER MOISMURE y6 DRY PCF MOISTURE % DRYDENSTY PCF COMPACTION COMMENT" 09/13 FG -6.0 1 20.5 99.5 21.9 94 95 - 159 160 09/13 FG -5.0 1 20.5 99.5 20.8 96 97 1 -A 161 09/13 FG -4.0 1 20.5 99.5 21.3 96 96 1 -A FG -3.0 1 20.5 99.5 21.0 95 96 1- 162 09/13 163 09/13 FG -2.0 1 20.5 99.5 20.7 96 97 1 -A 164 09/13 FG -1.0 1 20.5 99.5 21.5 96 97 1 -A 1 20.5 99.5 21.7 95 96 1- 165 1 09/13 FG TEST LOCATION: 159110" SANITARY SEWER LINE "D" @ STATION 1+75 160 110" SANITARY SEWER LINE "D" @ STATION 1 +50 161 110" SANITARY SEWER LINE "D" @ STATION 1 +25 162 110" SANITARY SEWER LINE "D" @ STATION 1 +00 163 110" SANITARY SEWER LINE "D" @ STATION 0 +75 164 110" SANITARY SEWER LINE "D" @ STATION 0 +50 165 110" SANITARY SEWER LINE "D" @ STATION 0 +25 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST Dav CGO1083 -18 ALPHA TESTI Stettner