Vista Properties-LR 960903A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
TESTED FOR:
CENTEX HOMES
C/O DOWDEY, ANDERSON & ASSOC.
DALLAS, TEXAS
REPORT OF FIELD
COMPACTION TESTS
DATE:
09/03/96
PROJECT: OUR REPORT NO.
SANITARY SEWER & WATER IMPROVEMENTS 96562 -16
VISTA RIDGE, AREA F
COPPELL /LEWISVILLE, TEXAS
TEST DATA:
TEST
NO.
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
%
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT"
134
09/03
FG -4.0
1
20.5
99.5
21.2
97
98
1 -A
135
09/03
FG -3.0
1
20.5
99.5 1
20.9
96
97
1 -A
136
09/03
FG -2.0
1
20.5
99.5
21.7
97
98
1 -A
137
09/03
FG -1.0
1
20.5
99.5
22.0
97
97
1 -A
138
09/03
FG
1
20.5
99.5
21.7
96
97
1 -A
139
09/03
FG -4.0
1
20.5
99.5
20.8
97
98
1 -A
140
09/03
FG -3.0
1
20.5
99.5
20.6
97
97
1 -A
TEST LOCATION:
134
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
2 +00
135
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
1 +50
136
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
1 +25
137
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
0 +75
138
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
0 +25
139
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
3 +25
140
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
3 +00
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
* A. TEST RESULTS COMPLY WITH SPECIFICATIONS
B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST
CGO1083 -18 Da
Res ully Submitted,
ALPHA TESTING, IN
S e
A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR: DATE:
CENTEX HOMES 09/03/96
C/O DOWDEY, ANDERSON & ASSOC.
DALLAS, TEXAS
PROJECT: OU R REPORT NO.
SANITARY SEWER & WATER IMPROVEMENTS 96562 -16A
VISTA RIDGE, AREA F
COPPELL /LEWISVILLE, TEXAS
A T A.
TEST
NO
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
%
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
COMPACTION
COMMENT
141
142
09103
09/03
FG -2.0
FG -1.0
1
1
20.5
20.5
99.5
99.5
21.6
20.9
97
98
97
99
1 -A
1 -A
FG
1
20.5
99.5
21.9
96
97
1 -A
143
09/03
141
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
2 +75
142
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
2 +50
143
SANITARY
SEWER
LINE
F
@
PAVING,
STATION
2 +25
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS - .Ae'spectfully Submitted,
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Atit�1A TESTIN
4. CEMENT TREATED D. RETEST -
David �P tettne.r