Vista Properties-LR 960830A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
TESTED FOR:
CENTEX HOMES
C/O DOWDEY, ANDERSON & ASSOC.
DALLAS, TEXAS
REPORT OF FIELD
COMPACTION TESTS
DATE:
08/30/96
PROJECT:
SANITARY SEWER & WATER IMPROVEMER EPORT NO. 96562 -15
VISTA RIDGE, AREA F
COPPELL /LEWISVILLE, TEXAS
TEST DATA:
TEST
NO.
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT'
127
08/30
FG -6.0
3
16.6
106.6
17.2
105
98
1 -A
128
08/30
FG -5.0
3
16.6
106.6
16.9
104
98
1 -A
129
08/30
FG -4.0
3
16.6
106.6
17.7
103
96
1 -A
130
08/30
FG -3.0
3
16.6
106.6
17.0
104
98
1 -A
131
08/30
FG -2.0
3
16.6
106.6
16.7
105
98
1 -A
132
08/30
FG -1.0
3
16.6
106.6
17.5
104
97
1 -A
133
08/30
FG
3
16.6
106.6
17.9
103
97
1 -A
TEST LOCATION:
127
18"
SANITARY
SEWER
LINE
A
@
STATION
13 +75
128
18"
SANITARY
SEWER
LINE
A
@
STATION
13 +25
129
18"
SANITARY
SEWER
LINE
A
@
STATION
13 +00
130
18"
SANITARY
SEWER
LINE
A
@
STATION
12 +75
131
18"
SANITARY
SEWER
LINE
A
@
STATION
12 +50
132
18"
SANITARY
SEWER
LINE
A
@
STATION
12 +25
133
18"
SANITARY
SEWER
LINE
A
@
STATION
12 +00
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS espectfully Submitted,
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTING
4. CEMENT TREATED D. RETEST _
CGOi -18 Da 4- 4--� St' ttn