Loading...
Vista Properties-LR 960830A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 TESTED FOR: CENTEX HOMES C/O DOWDEY, ANDERSON & ASSOC. DALLAS, TEXAS REPORT OF FIELD COMPACTION TESTS DATE: 08/30/96 PROJECT: SANITARY SEWER & WATER IMPROVEMER EPORT NO. 96562 -15 VISTA RIDGE, AREA F COPPELL /LEWISVILLE, TEXAS TEST DATA: TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 127 08/30 FG -6.0 3 16.6 106.6 17.2 105 98 1 -A 128 08/30 FG -5.0 3 16.6 106.6 16.9 104 98 1 -A 129 08/30 FG -4.0 3 16.6 106.6 17.7 103 96 1 -A 130 08/30 FG -3.0 3 16.6 106.6 17.0 104 98 1 -A 131 08/30 FG -2.0 3 16.6 106.6 16.7 105 98 1 -A 132 08/30 FG -1.0 3 16.6 106.6 17.5 104 97 1 -A 133 08/30 FG 3 16.6 106.6 17.9 103 97 1 -A TEST LOCATION: 127 18" SANITARY SEWER LINE A @ STATION 13 +75 128 18" SANITARY SEWER LINE A @ STATION 13 +25 129 18" SANITARY SEWER LINE A @ STATION 13 +00 130 18" SANITARY SEWER LINE A @ STATION 12 +75 131 18" SANITARY SEWER LINE A @ STATION 12 +50 132 18" SANITARY SEWER LINE A @ STATION 12 +25 133 18" SANITARY SEWER LINE A @ STATION 12 +00 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS espectfully Submitted, 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTING 4. CEMENT TREATED D. RETEST _ CGOi -18 Da 4- 4--� St' ttn