Vista Properties-LR 960821A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR: CENTEX HOMES DATE: 8/21/96
(F /K/A VISTA PARTNERS)
DALLAS, TEXAS
PROJECT- SANITARY SEWER & WATER OUR REPORT NO.
IMPROVEMENTS
COPPELL, TEXAS
TEST DATA:
96562 -10
TEST
NO.
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
%
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT'
89
08/21/96
FG - 6.0
1
20.5
99.5
21.6
97
97
1 -A
90
08/21/96
FG - 5.0
1
20.5
99.5
22.1
96
96
1 -A
91
08/21/96
FG - 4.0
1
20.5
99.5
21.0
97
97
1 -A
92
08/21/96
FG - 3.0
1
20.5
99.5
20.9
98
98
1 -A
93
08/21/96
FG - 2.0
1
20.5
99.5
21.3
96
97
1 -A
94
08/21/96
FG - 1.0
1
20.5
99.5
21.7
97
97
1 -A
95
08/21/96
FG
1
20.5
99.5
21.2
96
97
1 -A
TEST LOCATION: I "'
89
12" SANITARY SEWER LINE "D" STA:
7 + 45
90
12" SANITARY SEWER LINE "D" STA:
7 + 00
91
12" SANITARY SEWER LINE "D" STA:
6 + 75
92
12" SANITARY SEWER LINE "D" STA:
6 + 50
93
12" SANITARY SEWER LINE "D" STA:
6 + 25
94
12" SANITARY SEWER LINE "D" STA:
6 + 00
5
12" SANITARY SEWER LINE "D" STA:
5 + 75
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Rqlol Submitted,
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS f
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTING,
4. CEMENT TREATED D. RETEST DAV1 (P T NER
CGOIO63 -18 -
A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR: CENTEX HOMES DATE: 8/21/96
(F /K/A VISTA PARTNERS)
DALLAS, TEXAS
PROJECT: SANITARY SEWER & WATER OUR REPORT NO
IMPROVEMENTS
COPPELL, TEXAS
TEST DATA:
96562 -10 -A
TEST
NO.
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
y,
MAXIMUM LAB
DRY DENSITY
PC
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT`
96
08/21/96
FG - 4.0
1
20.5
99.5
22.0
95
96
1 -A
97
08/21/96
FG - 3.0
1
20.5
99.5
21.3
97
97
1 -A
98
08/21/96
FG - 2.0
1
20.5
99.5
20.9
97
97
1 -A
99
08/21/96
FG - 1.0
1
20.5
99.5
21.6
96
97
1 -A
100
08/21/96
FG
1
20.5
99.5
21.9
96
97
1 -A
101
08/21/96
FG - 4.0
1
20.5
99.5
223
96
96
1 -A
102
08/21/96
FG - 3.0
1
20.5
99.5
20.9
97
97
1 -A
TEST LOCATION:
96
12" SANITARY SEWER LINE "D" STA:
5 + 75
97
12" SANITARY SEWER LINE "D" STA:
5 + 50
98
12" SANITARY SEWER LINE "D" STA:
5+25
99
12" SANITARY SEWER LINE "D" STA:
5+00
100
12" SANITARY SEWER LINE "D" STA:
4+75
101
12" SANITARY SEWER LINE "C" STA:
0+75
1 102
12" SANITARY SEWER LINE "C" STA:
0+50
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Respmtf'ully Submitted,/
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTING
4. CEMENT TREATED D. RETEST (YDP ST 4TN E R�
c0oioe3 -1e
A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR: CENTEX HOMES DATE: 8/21/96
(F /K/A VISTA PARTNERS)
DALLAS, TEXAS
PROJECT: SANITARY SEWER & WATER OUR REPORT NO.
IMPROVEMENTS
COPPELL, TEXAS
TEST DATA:
96562 -10 -B
EST
TEST
DATE
ELEV.
SOIL ID
NUMBER
OPTIMUM
MOISTURE
%
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT'
103
08/21/96
FG - 2.0
1
20.5
99.5
21.6
97
97
1 -A
104
08/21/96
FG - 1.0
1
20.5
99.5
22.6
96
97
1 -A
105
08/21/96
FIG
1
20.5
99.5
21.0
97
97
1 -A
TEST LOCATION:"
103
12" SANITARY SEWER LINE "D" STA:
0 + 25
104
12" SANITARY SEWER LINE "D" STA:
0 + 10
105
12" SANITARY SEWER LINE "D" STA:
0 + 65
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Res11y Submitted,
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTING,
4. CEMENT TREATED D. RETEST �,DA�V T ER