Vista Properties-LR 960821A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR: CENTEX HOMES DATE: 8/21/96 (F /K/A VISTA PARTNERS) DALLAS, TEXAS PROJECT- SANITARY SEWER & WATER OUR REPORT NO. IMPROVEMENTS COPPELL, TEXAS TEST DATA: 96562 -10 TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 89 08/21/96 FG - 6.0 1 20.5 99.5 21.6 97 97 1 -A 90 08/21/96 FG - 5.0 1 20.5 99.5 22.1 96 96 1 -A 91 08/21/96 FG - 4.0 1 20.5 99.5 21.0 97 97 1 -A 92 08/21/96 FG - 3.0 1 20.5 99.5 20.9 98 98 1 -A 93 08/21/96 FG - 2.0 1 20.5 99.5 21.3 96 97 1 -A 94 08/21/96 FG - 1.0 1 20.5 99.5 21.7 97 97 1 -A 95 08/21/96 FG 1 20.5 99.5 21.2 96 97 1 -A TEST LOCATION: I "' 89 12" SANITARY SEWER LINE "D" STA: 7 + 45 90 12" SANITARY SEWER LINE "D" STA: 7 + 00 91 12" SANITARY SEWER LINE "D" STA: 6 + 75 92 12" SANITARY SEWER LINE "D" STA: 6 + 50 93 12" SANITARY SEWER LINE "D" STA: 6 + 25 94 12" SANITARY SEWER LINE "D" STA: 6 + 00 5 12" SANITARY SEWER LINE "D" STA: 5 + 75 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Rqlol Submitted, 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS f 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTING, 4. CEMENT TREATED D. RETEST DAV1 (P T NER CGOIO63 -18 - A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR: CENTEX HOMES DATE: 8/21/96 (F /K/A VISTA PARTNERS) DALLAS, TEXAS PROJECT: SANITARY SEWER & WATER OUR REPORT NO IMPROVEMENTS COPPELL, TEXAS TEST DATA: 96562 -10 -A TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE y, MAXIMUM LAB DRY DENSITY PC IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT` 96 08/21/96 FG - 4.0 1 20.5 99.5 22.0 95 96 1 -A 97 08/21/96 FG - 3.0 1 20.5 99.5 21.3 97 97 1 -A 98 08/21/96 FG - 2.0 1 20.5 99.5 20.9 97 97 1 -A 99 08/21/96 FG - 1.0 1 20.5 99.5 21.6 96 97 1 -A 100 08/21/96 FG 1 20.5 99.5 21.9 96 97 1 -A 101 08/21/96 FG - 4.0 1 20.5 99.5 223 96 96 1 -A 102 08/21/96 FG - 3.0 1 20.5 99.5 20.9 97 97 1 -A TEST LOCATION: 96 12" SANITARY SEWER LINE "D" STA: 5 + 75 97 12" SANITARY SEWER LINE "D" STA: 5 + 50 98 12" SANITARY SEWER LINE "D" STA: 5+25 99 12" SANITARY SEWER LINE "D" STA: 5+00 100 12" SANITARY SEWER LINE "D" STA: 4+75 101 12" SANITARY SEWER LINE "C" STA: 0+75 1 102 12" SANITARY SEWER LINE "C" STA: 0+50 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Respmtf'ully Submitted,/ 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTING 4. CEMENT TREATED D. RETEST (YDP ST 4TN E R� c0oioe3 -1e A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR: CENTEX HOMES DATE: 8/21/96 (F /K/A VISTA PARTNERS) DALLAS, TEXAS PROJECT: SANITARY SEWER & WATER OUR REPORT NO. IMPROVEMENTS COPPELL, TEXAS TEST DATA: 96562 -10 -B EST TEST DATE ELEV. SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 103 08/21/96 FG - 2.0 1 20.5 99.5 21.6 97 97 1 -A 104 08/21/96 FG - 1.0 1 20.5 99.5 22.6 96 97 1 -A 105 08/21/96 FIG 1 20.5 99.5 21.0 97 97 1 -A TEST LOCATION:" 103 12" SANITARY SEWER LINE "D" STA: 0 + 25 104 12" SANITARY SEWER LINE "D" STA: 0 + 10 105 12" SANITARY SEWER LINE "D" STA: 0 + 65 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Res11y Submitted, 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTING, 4. CEMENT TREATED D. RETEST �,DA�V T ER C001003-18