Loading...
Vista Properties-LR 960814A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR: CENTEX HOMES DATE: 8/14/96 (F /K/A VISTA PARTNERS) DALLAS, TEXAS PROJECT: SANITARY SEWER & WATER OUR REPORT NO. IMPROVEMENTS COPPELL, TEXAS TEST DATA: 96562 -5 -A TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE q, MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 37 08/14/96 FG - 13.0 1 20.5 99.5 21.6 97 97 1 -A 38 08/14/96 FG - 12.0 1 20.5 99.5 22.5 97 97 1 -A 39 08/14/96 FG - 11.0 1 20.5 99.5 21.7 97 97 1 -A 40 08/14/96 FG - 10.0 1 20.5 99.5 22.8 97 97 1 -A 41 08/14/96 FG - 9.0 1 20.5 99.5 22.0 96 97 1 -A 42 08/14/96 FG - 8.0 1 20.5 99.5 21.6 98 98 1 -A 43 08/14/96 FG - 7.0 1 1 1 20.5 1 99.5 1 21.9 1 97 1 97 1 -A TEST LOCATION: 37 18" SANITARY SEWER LINE "B" AT STA: 6 + 75 38 18" SANITARY SEWER LINE "B" AT STA: 6+50 39 18" SANITARY SEWER LINE "B" AT STA: 6+00 40 18" SANITARY SEWER LINE "B" AT STA: 5+75 41 18" SANITARY SEWER LINE "B" AT STA: 5+50 42 18" SANITARY SEWER LINE "B" AT STA: 5+25 43 18" SANITARY SEWER LINE "B" AT STA: 5+00 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Respectfull miffed, 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS A TESTING, INC 4. CEMENT TREATED D. RETEST D (P N R CGOIO83 -1e A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR: CENTEX HOMES DATE: 8/14/96 (F /K/A VISTA PARTNERS) DALLAS, TEXAS PROJECT: SANITARY SEWER & WATER OUR REPORT NO. IMPROVEMENTS COPPELL, TEXAS TEST DATA: 96562 -5 -B TEST NO DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 44 08/14/96 FG - 6.0 1 20.5 99.5 21.3 98 98 1 -A 45 08/14/96 FG - 5.0 1 20.5 99.5 22.0 96 97 1 -A 46 08/14/96 FG - 4.0 1 20.5 99.5 21.7 96 97 1 -A 47 08/14/96 FG - 3.0 1 20.5 99.5 22.6 95 96 1 -A 48 08/14/96 FG - 2.0 1 20.5 99.5 21.3 97 97 1 -A 49 08/14/96 FG - 1.0 1 20.5 99.5 21.4 97 98 1 -A 50 08/14/96 FG 1 20.5 99.5 21.8 97 97 1 -A TEST LOCATION: 44 18" SANITARY SEWER LINE "B" AT STA: 4 + 75 45 18" SANITARY SEWER LINE "B" AT STA: 4+50 46 18" SANITARY SEWER LINE "B" AT STA: 5+25 47 18" SANITARY SEWER LINE "B" AT STA: 6+25 48 18" SANITARY SEWER LINE "B" AT STA: 6+50 49 18" SANITARY SEWER LINE "B" AT STA: 7+00 50 18" SANITARY SEWER LINE "B" AT STA: 5+50 1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Respectful! Itted, 2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS PHA TESTING, INC 4. CEMENT TREATED D. RETEST ID A ER CGOIO 3-1a