Vista Properties-LR 960814A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR: CENTEX HOMES DATE: 8/14/96
(F /K/A VISTA PARTNERS)
DALLAS, TEXAS
PROJECT: SANITARY SEWER & WATER OUR REPORT NO.
IMPROVEMENTS
COPPELL, TEXAS
TEST DATA:
96562 -5 -A
TEST
NO.
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
q,
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT'
37
08/14/96
FG - 13.0
1
20.5
99.5
21.6
97
97
1 -A
38
08/14/96
FG - 12.0
1
20.5
99.5
22.5
97
97
1 -A
39
08/14/96
FG - 11.0
1
20.5
99.5
21.7
97
97
1 -A
40
08/14/96
FG - 10.0
1
20.5
99.5
22.8
97
97
1 -A
41
08/14/96
FG - 9.0
1
20.5
99.5
22.0
96
97
1 -A
42
08/14/96
FG - 8.0
1
20.5
99.5
21.6
98
98
1 -A
43
08/14/96
FG - 7.0
1 1
1 20.5
1 99.5
1 21.9
1 97
1 97
1 -A
TEST LOCATION:
37
18" SANITARY SEWER LINE "B" AT STA:
6 + 75
38
18"
SANITARY SEWER LINE "B" AT STA:
6+50
39
18"
SANITARY SEWER LINE "B" AT STA:
6+00
40
18"
SANITARY SEWER LINE "B" AT STA:
5+75
41
18" SANITARY SEWER LINE "B" AT STA:
5+50
42
18"
SANITARY SEWER LINE "B" AT STA:
5+25
43
18"
SANITARY SEWER LINE "B" AT STA:
5+00
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Respectfull miffed,
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS A TESTING, INC
4. CEMENT TREATED D. RETEST
D (P N R
CGOIO83 -1e
A ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(214) 620 -8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR: CENTEX HOMES DATE: 8/14/96
(F /K/A VISTA PARTNERS)
DALLAS, TEXAS
PROJECT: SANITARY SEWER & WATER OUR REPORT NO.
IMPROVEMENTS
COPPELL, TEXAS
TEST DATA:
96562 -5 -B
TEST
NO
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
%
MAXIMUM LAB
DRY DENSITY
PCF
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT'
44
08/14/96
FG - 6.0
1
20.5
99.5
21.3
98
98
1 -A
45
08/14/96
FG - 5.0
1
20.5
99.5
22.0
96
97
1 -A
46
08/14/96
FG - 4.0
1
20.5
99.5
21.7
96
97
1 -A
47
08/14/96
FG - 3.0
1
20.5
99.5
22.6
95
96
1 -A
48
08/14/96
FG - 2.0
1
20.5
99.5
21.3
97
97
1 -A
49
08/14/96
FG - 1.0
1
20.5
99.5
21.4
97
98
1 -A
50
08/14/96
FG
1
20.5
99.5
21.8
97
97
1 -A
TEST LOCATION:
44
18" SANITARY SEWER LINE "B" AT STA:
4 + 75
45
18" SANITARY SEWER LINE "B" AT STA:
4+50
46
18" SANITARY SEWER LINE "B" AT STA:
5+25
47
18" SANITARY SEWER LINE "B" AT STA:
6+25
48
18" SANITARY SEWER LINE "B" AT STA:
6+50
49
18" SANITARY SEWER LINE "B" AT STA:
7+00
50
18" SANITARY SEWER LINE "B" AT STA:
5+50
1. FILL A. TEST RESULTS COMPLY WITH SPECIFICATIONS Respectful! Itted,
2. NATURAL SUBGRADE B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS PHA TESTING, INC
4. CEMENT TREATED D. RETEST ID A ER
CGOIO 3-1a